GB
│
IE
│
5
■
PDSP 1000 E6
Operation
Mount the collecting bag
for sandblasting material
■
Use a screwdriver to attach the collecting
bag to the appliance with the supplied
screw clip .
Select and fitting attachments
■
Start by selecting the appropriate attachment
for the job at hand ( , , , ).
■
Push the selected attachment firmly onto the jet
nozzle , ensuring that no air can escape from
the sides.
Filling the blasting medium container
CAUTION!
►
Before you open the screw cap on the
blasting medium container , or make any
other settings, the connection to the
compressed air hose must be disconnected
and all pressure completely discharged.
■
Use only suitable blasting media for your
sandblasting work.
NOTE
►
We recommend using a blasting medium
(ground blast furnace slag) with a grain size
of 0.2–0.8 mm and which has been shown
not to cause silicosis.
■
Please ensure that the blasting medium is
totally dry and not too coarse-grained.
NOTE
►
The maximum grain size is 0.8 mm.
■
Open the screw cap on the blasting medium
container by turning it anticlockwise.
■
Fill the required amount of blasting medium
into the blasting medium container .
■
Ensure that you do not exceed the maximum
fill level for the container of 900 ml.
■
Afterwards, close the screw cap on the
blasting medium container by turning it
clockwise.
NOTE REGARDING THE BLASTING
MEDIUM GRAIN SIZE
►
The larger/coarser the grain size of the
blasting medium used, the coarser the dirt
that can be removed using it. The supplied
material, on the other hand, is fine and thus
more suitable for the removal of items such as
paint or rust film. The fine material also
causes less damage to the surfaces being
treated, meaning a choice can be made
regarding these.
For coarse rust, for example, it is best to use a
coarser-grained blasting medium which you
can buy online (see section "Importer") or in
any good specialist retailer. Please observe
the guidelines regarding maximum grain size.
Connecting the compressed air
supply
NOTE
►
The compressed air sandblaster gun may
only be operated on cleaned, condensate-
and oil-free compressed air and may not
exceed the maximum operating pressure of
6.3 bar at the appliance.
To ensure that you can regulate the air pres-
sure, the compressed air source should be
equipped with a (filter) pressure reducer.
♦
Connect the compressed air sandblaster gun
to a suitable compressed air source by attaching
the quick-connect coupling on the supply hose
to the nipple on the sandblaster gun .
The connection locks automatically.
NOTE
►
Ensure that the control dial is set to
before connecting the appliance to the
compressed air source.
Содержание 373219 2104