PAK 20-Li A1 / PALP 20-Li A1
GB
│
IE
│
17
■
Package contents
1 battery charger PLG 20 A1
1 rechargeable battery PAP 20 A1
1 cordless compressor PAK 20-Li A1
incl. 1 x hose with valve adapter
incl. 2 x inner-tube valves (1 x Dunlop/express
valve, 1 Presta valve)
incl. 1 x ball needle
incl. 3 x plastic adapters
1 cordless air pump PALP 20-Li A1
incl. 3 x plastic adapters (universal adapter for
valves with an internal diameter of approx.
8 mm, adapter screw valve, e.g. for bathing
boats, adapter for deflation valves)
1 carrying case
1 set of operating instructions
Technical data
Cordless compressor: PAK 20-Li A1
Rated voltage:
20 V
(DC)
Max. pressure:
7 bar (100 psi)
Cordless air pump: PALP 20-Li A1
Rated voltage:
20 V
(DC)
Air flow rate:
70 m³/h
Use only the following battery to operate
the cordless tools:
PAP 20 A1:
Type:
LITHIUM
ION
Cells: 5
Rated voltage:
20 V
(DC)
Capacity: 2.0
Ah
Use only the following charger to charge
the battery pack: PLG 20 A1
INPUT:
Rated voltage:
230–240 V ∼, 50 Hz
(AC)
Rated power consumption: 65 W
OUTPUT:
Rated voltage:
21.5 V
(DC)
Charging current:
2.4 A
Charging time:
approx. 60 min
Fuse (internal):
3.15 A
T3.15A
Protection class:
II / (double insulation)
Noise emission value:
The measured values have been determined in
accordance with EN 60745. The A-rated noise
level of the tool is typically:
Cordless compressor:
Sound pressure level: L
PA
= 68.3 dB(A)
Uncertainty: K
PA
=
3 dB
Sound power level:
L
WA
= 79.3 dB(A)
Uncertainty: K
WA
=
3 dB
Cordless air pump:
Sound pressure level: L
PA
= 72.3 dB(A)
Uncertainty: K
PA
=
3 dB
Sound power level:
L
WA
= 83.3 dB(A)
Uncertainty: K
WA
=
3 dB
Total vibration value:
Total vibration values (vector total of three direc-
tions) determined in accordance with EN 60745:
Cordless compressor:
Vibration emission value: ah = 2.645 m/s²
Uncertainty: K = 1.5 m/s²
Cordless air pump:
Vibration emission value: ah = 2.599 m/s²
Uncertainty: K = 1.5 m/s²
NOTE
►
The vibration level specified in these instruc-
tions has been measured in accordance with
a standardised measuring procedure and
can be used for equipment comparisons. The
specified vibration emission value can also
be used to make an initial exposure estimate.