A/C Component Notes:
The High Pressure Hose is
connected to the fitting on the Compressor closest to the
outside of the cabinet, with the Low Pressure Hose being
connected to the fitting on the Compressor closest to the
engine. The High Pressure Switch is then connected to the
charging port on the High Pressure Hose, and the Low
Pressure Switch is connected to the charging port on the
Low Pressure Hose.
Wiring Harness Notes:
The Fuse Box located on the Wiring
Harness contains all of your APU’s fuses and relays,
including (7) 40 AMP Mini Fuses, (1) 2 AMP Mini Fuse, (1) 5
AMP Mini Fuse, (2) 5-Pin Relays, and (5) 4-Pin Relays.
PE Valve Notes:
The Diagram to the right displays which
A/C components are connected to each of the fittings on a
PE Valve. Misplacement of these components can result in
a malfunction of the APU.