* If you are experiencing issues with your APU Commander, disconnect the power for up to one hour to reboot the system.
47 |
Page
Error displays on screen:
“Charging system failure”
The charging system
has failed
More power is being
used than the APU is
generating.
Make sure all battery cables are tight and corrosion free.
Make sure all electrical components are securely plugged in.
Check the alternator belt and replace it if necessary.
Check the fuse panel for any blown fuses
Make sure the battery charge set point is not set too low. 12.4V is a
good starting point
Ensure an inverter or other device is not drawing more than 1000W
continuously.
Error displays on screen:
“High A/C Pressure Fault”
High head pressure
Fan is turning in the
wrong direction or
not working.
Check condenser and evaporator for air restriction.
Make sure the condenser fan is running. If not, check or replace the
fuse.
If the fan is not functioning, contact a service center near you.
Make sure the operating pressures are correct (A/C System
Maintenance).
Error displays on screen:
“Low A/C Pressure Fault”
Low refrigerant
Make sure the condenser fan is running. If not, check or replace the
fuse.
Check all hoses and fittings for refrigerant leaks.
Make sure the operating pressures are correct (A/C System
Maintenance).
Screen has frozen or
buttons do not respond
Calibration needed
Calibrate the screen by disconnecting the power, then pressing and
holding one finger on the screen while reconnecting the power. Once
the calibration screen appears, following the prompts on the screen.
Содержание HP2000 XTREME Series
Страница 1: ......
Страница 2: ...2 Page ...
Страница 63: ...A C Components Diagram 63 Page ...
Страница 64: ...Maintenance Components Diagram 64 Page ...
Страница 66: ...P ARKS I NDUSTRIES LLC 15460 Crabtree School Road Marion IL 62959 618 997 9608 www hp2000apu com 66 Page ...
Страница 67: ...67 Page ...
Страница 68: ...68 Page ...