background image

33615 Rev. D 

     

https://www.lantronix.com/

  

Page 

1

 of 

2

 

 

S3290  

Remotely Managed NID with Built-in Traffic Generator 

Quick Start Guide 

Cautions and Warnings

See the related Install Guide for specific Cautions and Warnings. Failure to read and 

understand the information there could result in poor equipment performance, damage to the equipment, or injury 

to persons.

 

There are two ways to log in to the S3290: 

1. 

Web

 

UI

: The S3290 supports the latest version of most popular Web browsers from any port.   

2. 

Console

 

Port

: using industry standard CLI. The S3290 has DHCP enabled by default. After power up, if a 

DHCP server is available, the S3290 will obtain an IP address from the DHCP server. If no DHCP server is 

available, after 60 seconds, the S3290 will fall back to the default IP address of 192.168.0.1/24. 

Login via Web UI 

1. Enter the default IP address in the browser URL field: 

192.168.0.1/24. 

 

2. Enter the Login information: Username: admin and Password: <Enter>.  

The Username is case sensitive (all lower case). 

 

Front Panel (S3290-24)  

 

Note:

 By default, Gigabit Ethernet 1/1 

(PORT 1)

 is configured as a 

Local Management

 port.  It is 

associated/configured by default as 

Private VLAN 6

.   

Local Management Port 1 can be changed to a normal data UNI/NNI port, if required. Subsequently, any Port can 

be configured as a management and/or normal data port.    
To remove Port 1 as local management and assign it as a normal facing data 

port:  
1.  Click on Configuration > Private VLANs > Membership. 
2.  Uncheck PVID 6 Port 1 and Save.  
3.  Check Port 1 with PVID 1 then Save. 

 

To save the running configuration to the start-up configuration, click 

Maintenance > Configuration > Save 

startup-config

 

Отзывы: