background image

12 

JINCHI05 REV E. 11/11/2014 

C

OMPETENT 

P

ERSONS 

S

CHEME

 

Members of the following schemes may self-certify the installation of this stove.  If the installer is not a member 
of one of these schemes, your local Building Control Department must approve the installation. 
 

Scheme

 

Web address

 

Telephone

 

APHC (Association of Plumbing and 
Heating Contractors (Certification) 
Limited 

www.aphc.co.uk

 

0121 711 5030 

Building Engineering Services 
Competence Accreditation (BESCA 
Limited) 

www.hvca.org.uk

 / 

www.besca.org.uk

 

0800 652 5533 

HETAS Ltd (Heating Equipment Testing 
and Approval Scheme) 

www.hetas.co.uk

 

01684 278170 

NAPIT Registration Ltd 

www.napit.org.uk

 

01623 811483 

NICEIC Group Ltd 

www.niceic.com

 

0870 013 0389 

 
F

LUE 

D

RAUGHT

 

A flue draught of minimum 1.2mm to a maximum 
2.5mm  water  gauge  is  required  for  satisfactory 
appliance performance.  
The flue  draught  should be  checked under fire  at 
high  output  with  windows  and  doors  closed.  To 
take the reading cover all air intakes (e.g. foil) and 
put a hole through the covering where the top air 
intake  is  for  the  probe  to  go  through  to  take  the 
reading. 
If  it  exceeds  the  recommended  maximum,  a 
draught stabiliser must be fitted so that the rate of 
burning  can  be  controlled  and  to  prevent  over 
firing. If the reading is less than the recommended 
minimum  then  the  performance  of  the  appliance 
will be compromised. 
 

C

ONNECTION TO THE CHIMNEY

/

FLUE SYSTEM

 

The  gap  between  the  old  fireplace  and  stove  flue 
outlet  must  be  filled  in  so  that  there  is  a  smooth 
streamlined entry into the flue way.  It  is essential 
that  all  connections  between  the  stove  and 
chimney-flue are sealed and made airtight. Both the 
chimney  and  any  flue  pipe  must  be  accessible  for 
cleaning and if ANY parts of the chimney cannot be 
reached through the stove (with baffle removed), a 
soot  door  must  be  fitted  in  a  suitable  position  to 
enable this to be done. 
 

A

IR 

S

UPPLY

 

Where  necessary,  any  air  opening  must  be  kept 
clear of blockage or obstruction.  Due consideration 
should be given to air requirements for any other 
appliances in the same room or space. 

M

ATERIAL 

C

LEARANCES

 

Any  non-combustible  walls  within  50mm  of  this 
appliance  should  be  at  least  200mm  thick  and 
should  extend  300mm  above  the  top  of  the 
appliance and at least 1.2 metres above the hearth. 
Any walls more than 50mm from the appliance may 
be  reduced  to  a  thickness  of  75mm.  Ensure  the 
inter-connecting  flue  pipe  also  has  adequate 
clearances to combustible materials. 
 
A  hearth  with  a  minimum  thickness  of  125mm 
should be provided. The hearth should extend to at 
least 300mm in front  of the  stove  and 150mm at 
the  sides,  and  should  be  in  accordance  with  the 
current  building  regulations.  In  all  instances  the 
hearth and fireplace recess should be made of non-
combustible material. 
 
The  appliance  shall  be  installed  on  a  floor  with 
adequate  load-bearing  capacity.  If  the  existing 
construction  does  not  meet  this  prerequisite, 
suitable  measures  (e.g.  load  distributing  plate) 
should be taken to achieve it. 
 

M

ATERIAL 

C

LEARANCES

 

Minimum Distances to Combustible Material 

Above the stove 

200mm 

At the side of the stove 

150mm 

Nearest Side Wall 

310mm 

In front of the stove 

900mm 

 
Note: combustible material refers to any material 
that  will  degrade  when  subjected  to  heat  (e.g. 
plaster) 

Содержание Chevin Inset 5 MKII

Страница 1: ...1 JINCHI05 REV E 11 11 2014 Chevin Inset 5 MKII Model CVSCHI05FM Instructions for Installation Operation Maintenance Servicing Approved for use in the United Kingdom and the Republic of Ireland ...

Страница 2: ...ls Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles and the surface finish of the appliance The Warranty will only be valid if the appliance is installed by an appropriately qualified engineer in accordance with the manufacturer s instructions and to the appropriate Building Regulations and or Local By Laws and serviced within 12 months of installation Parkra...

Страница 3: ... on or near this appliance Do not place furniture or other items within 1 metre of the front of this appliance See the note on material clearances on page 13 Extractor Fans and or Cooker Hoods must not be installed in the same space or room as this can cause the appliance to emit fumes into the room Do not obstruct the ventilation required for the safe use of this appliance COMPETENT PERSONS SCHEM...

Страница 4: ...times FUME EMISSION Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and refueling may occur Persistent fume emission must not be tolerated This appliance should not be operated with the door open If fume emission does persist then the following action should be taken immediately Open Doors and windows to ventilate room Let the fire out or eject an...

Страница 5: ... in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell It is non toxic but for your comfort we would suggest that during this period you leave all doors and windows open AIR CONTROLS This stove has been designed to burn cleaner and more efficiently than a conventional wood burning stove If used correctly this stove will bur...

Страница 6: ...rols open Allow the fuel to reach a steady glow and build the fire up gradually Once you have a good fire established across the grate bed further fuel can be added as required LOADING THE APPLIANCE WOOD With a full load of wood the stove will need to be refuelled approximately once every hour and a half Wood can be stacked higher in the stove than solid mineral fuel but care must be taken that lo...

Страница 7: ...n and adjust the secondary air to give the desired heat output Never leave the stove unattended until you are certain that the flames are fully established Avoid refuelling on to a low fire bed as this may cause excessive smoke emission Ensure there are sufficient embers to ignite the new fuel rapidly Alternatively add some more kindling before adding larger pieces of firewood Do not add firewood ...

Страница 8: ...Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised...

Страница 9: ...itable for use in a shared flue Read and follow the operating instructions Use only recommended fuels This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke Control Area Find out if you are in a Smoke Control Area by contacting your Local Authority The Chevin Inset 5 has been fitted with a permanent bypass that prevents closure of the secondary air slider Re...

Страница 10: ...ting the chimney flue system Make provision to access the chimney flue system for cleaning and the removal of debris If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS4543 can be used These chimneys must be fitted in accordance with the manufacturer s instruction...

Страница 11: ... satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws European and National Standards and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirem...

Страница 12: ...e way It is essential that all connections between the stove and chimney flue are sealed and made airtight Both the chimney and any flue pipe must be accessible for cleaning and if ANY parts of the chimney cannot be reached through the stove with baffle removed a soot door must be fitted in a suitable position to enable this to be done AIR SUPPLY Where necessary any air opening must be kept clear ...

Страница 13: ... retainer by lifting the right hand side until it will clear the opening and remove 3 Remove the catch bar front plate by lifting the right hand side until it will clear the opening and remove 4 Remove the grate bars by lifting them away from the cam bar and pulling forward out of the rear grate support The singular bars should be removed first noting their positions low or high leaving the two st...

Страница 14: ...ck 7 Unscrew the 2 M6 Screws and remove the Turbo Bars 8 Pull the top edge of the Lower Side Bricks forward and remove You will now be able to remove the Lower Rear Brick 9 You can now remove the Side Riddling Bars 10 Remove the cam bar by firstly sliding it to the right until the left hand end is clear of the hole 11 Then maneuver the free end into the void in the front left hand side of the Stov...

Страница 15: ... the hearth or paintwork on the stove and making sure that the 12mm rope seal is compressed forming a tight seal between the stove and fireplace 4 Drill into the existing fireback through the fixing holes in the body see below using a 6mm drill bit 5 Place the screws provided into the fixing holes and gently tighten until the stove feels secure 6 Fill the fixing holes with fire cement to form an a...

Страница 16: ...e appliance to heat up slowly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the Door and carry out a spillage test using a smoke match around the door opening If there is excessive spillage please allow the appliance to cool and then re check the chimney flue system and ventilation Do not run the stove at full output for at leas...

Страница 17: ... these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming of the doors could crack the glass panels The glass will not fracture from heat Should you need to replace a glass panel please ensure you purchase a new Gasket at the same time Please check periodically that the glass clips and screws have not become loose They s...

Страница 18: ...cleaner if required If the Gasket is torn or damaged we recommend that is replaced to ensure that no products of combustion enters the room when the appliance is used Brush down the outer surface and touch up the paint if necessary Burn the appliance at a low rate after maintenance to allow any new seals paint or glue cure properly The appliance may emit unpleasant odours during this process pleas...

Страница 19: ...ES AND STOVE CARE Single Door Assembly Single Door HCE09008 Glass Clip HHR08146 Glass Clip Screw FSJM05008SS Single Door Glass HCE09102 Single Door Gasket HCE09101 Door Handle Assembly TDI05ARRT011MB Rope Sealing Kit SCPCB900SDRSK REVC ...

Страница 20: ...Double Door Glass HCE09031 Double Door Gasket HCE09030 Right Hand Door HCE09009 Rope Sealing Kit SCPCB900DDRSK Glass Clip HHR08046 Glass Clip Screw FSJM05008SS Double Door Glass HCE09031 Double Door Gasket HCE09030 Door Handle Assembly TDI05ARRT012MB Door Handle Assembly Door Handle Boss AVI05010MB Door Handle Stainless AVA08020MB Hex Screw FSHM08050 ...

Страница 21: ...ars Side CNN05004 A B Upper CNS04013 Lower CNS04012 Ashpan HCN05ARRT033 Operating Tool HFR07040 Secondary Air Control Support Plate HCN05050 Slider Plate HH06086 Gasket HH06088 Slider Shaft HCN05016 Slider Knob HCE06059S Upper Side Brick HCN05073 A B Lower Side Brick HCN05071 A B Door Hinge HH06050 Hinge Pin FRRE08 1 75 Catch Bar Single Door HCN05ARRT0019 Double Door HCN05ARRT020 Primary Air Contr...

Страница 22: ...de Appliance Description Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has this appliance passed the flue draught test Please write down the flue draught reading Has this appliance passed the smoke test Has this appliance passed the spillage test Have you explain...

Страница 23: ...Servicing Company Engineer Signature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Signature 4th Service Date of Service Date of next Service Servicing Company Engineer Signature 6th Service Date of Service Date of next Service Servicing Company Engineer Signature 8th Service Date of...

Страница 24: ...24 JINCHI05 REV E 11 11 2014 ...