PRE-INSTALLATION REQUIREMENTS
W
ARNING
!
You run the risk of serious health problems if the
products of combustion enter the property.
P
LEASE CHECK THE FOLLOWING
:
Any existing chimney/flue system must be
confirmed as suitable for this appliance as defined
in Building Regulations Document J.
It must be swept and inspected, by a competent
person (see notes), to confirm that is structurally
sound and free from cracks and obstructions.
The diameter of the Flue should not be less than
Ø125mm and not more than Ø230mm. Do not
connect to systems that have large voids or
spaces. If any of these requirements are not met,
the chimney should be lined by a suitable method.
If the chimney is suspected of previously serving
an open fire it must be swept again, within a
month of regular use, to clear any soot that may
have been dislodged due to the variation in
combustion levels and higher flue gas
temperature levels.
The chimney/flue system exit must comply with
Building Regulations Document J
The minimum height of the chimney/flue system
must be 4.5 metres from the hearth to the top
exit. There must be no horizontal sections and
must not have more than 4 bends. These bends
must have angles of 45° or less.
Make provision to remove the appliance without
affecting the chimney/flue system. Make provision
to access the chimney/flue system for cleaning
and the removal of debris.
If there is no existing chimney then either a
prefabricated block chimney in accordance with
Building Regulations Approved Document J, or a
twin-walled insulated stainless steel flue to BS4543
can be used. These chimneys must be fitted in
accordance with the manufacturer’s instructions
and Building Regulations. New masonry and flue
block chimneys must meet the requirements of
Building Regulations Document J. Any connecting
flue pipe systems must also meet these regulations.
Please check the suitability of the fireplace and/or
surround for use with this appliance before
installing it.
Many Fire Surrounds are only suitable for use with
gas and electric fires and therefore may not suitable
for this Solid Fuel Appliance. Please check you Fire
Surround.
Fire Surround Back Panels suitable for solid fuel are
usually in three sections and slabbed.
This product is
designed to fit into a
standard 16 inch fire
back.
An optional Flue
Adaptor (for Ø125mm
flexible liners) is
supplied with this
Appliance.
(Note! Remove bolt-in
Flue Infill Plate prior to
assembly)
The upper section of the fire back will need to be
removed to fit the flue adaptor.
If you have any doubts about the suitability of
your chimney, consult your local Dealer/Stockist
or Installation Engineer.
Parkray Stoves cannot be held responsible for any
fault arising through incorrect use or installation.