26
TROUBLESHOOTING
ISSUE
CAUSE
RESOLUTION
OP
ER
ATI
ON
Problem starting the fire and
keeping it burning
Low flue draught
Speak to your installer
Wood with moisture content over 20%
Ensure use of dry seasoned wood
with less than 20% moisture content
Unable to control fire
High flue draught
Speak to your installer
Short burn time
Wood with moisture content over 20%.
Insufficient amount of fuel
–
refer to page 15
(Notes on Woodburning)
Ensure use of dry seasoned wood
with less than 20% moisture content
Over firing
High flue draught
Speak to your installer
Air controls left fully open
Close air control to reduce output
Low heat output
Low flue draught
Speak to your installer about advice
on a suitable flue system.
Wet wood (over 20% moisture content)
Ensure use of dry seasoned wood
with less than 20% moisture content
Excessive fuel consumption
High flue draught
Speak to your installer
Over dry wood
Do not use constructional timber of
pallet wood
SM
OK
E PROBLEM
S
Smoke and small flames
Wood with moisture content over 20%
Ensure use of dry seasoned wood
with less than 20% moisture content
Excessive smoke spillage into
room when appliance door is
opened
Low flue draught
Speak to your installer
Incorrect additional ventilation air in to the
building
Speak to your installer
Continuous smoke spillage into
the room when stove is in use
Blocked flue
Open all doors and windows to
ventilate the room. Allow the fire to
go out. Check flue for blockage. Do
not re-use until the problem has been
identified. If in doubt speak to your
installer.
Blue/grey smoke from chimney
Wood with moisture content over 20%
Ensure use of dry seasoned wood
with less than 20% moisture content
ADV
ERSE
W
EATHER
Windy days causing spillage into
the room
Down draught in flue caused by air
turbulence due to nearby buildings or trees.
Weather conditions combined with
the flue terminal position can have an
effect on the stoves performance.
Speak to your installer.
Calm days causing spillage into
the room
Over size flue giving poor flue draught
Weather conditions combined with
the flue terminal position can have an
effect on the stoves performance.
Speak to your installer.
Damp/Rainy days lighting and
burning problems
Flue temperature low or rain water inside
flue.
Use good quality wood to start and
maintain the fire, speak to your
installer to fit a rain cowl.
Wind noise
High flue draught
Speak to your installer.
Содержание ASPECT 14
Страница 13: ...13 Dimensions Aspect 6 Dimensions Aspect 7 Dimensions Aspect 8 Slimline ...
Страница 14: ...14 Dimensions Aspect 8 Dimensions Aspect 9 Dimensions Aspect 14 ...
Страница 31: ...31 BODY ASSEMBLY SPARES ASPECT COMPACT 5 AND 5 BODY ASSEMBLY SPARES ASPECT 5 SLIMLINE ...
Страница 32: ...32 BODY ASSEMBLY SPARES ASPECT 6 BODY ASSEMBLY SPARES ASPECT 7 ...
Страница 33: ...33 BODY ASSEMBLY SPARES ASPECT 8 BODY ASSEMBLY SPARES ASPECT 8 SLIMLINE ...
Страница 34: ...34 BODY ASSEMBLY SPARES ASPECT 9 BODY ASSEMBLY SPARES ASPECT 14 ...