TECHNICAL DATA
DIMENSIONS
Height
Width
Depth
Height to hotplate
900mm (nominal)
554mm (nominal)
600mm
(to front of
door panel)
Space for fixing at hotplate level
2mm minimum clearance
Space for fixing above hotplate level
See important note 'Location of Appliance' page 41.
Minimum space above hotplate
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance
61kg.
Minimum distance from rear wall
5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas
Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric
220V/240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
IGNITION
Spark generator
APCO 6 + 1 MG7424/1
GRILL
Natural Gas
L.P. Gas
Heat Input
3.3kW (11263 Btu/h)
3.0kW (215g/h)
Injector Marking
138
88
HOTPLATE
Natural Gas
R.H.F.
R.H.R.
L.H.R. L.H.F
Heat Input
1.0kW
2.0kW
2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h) (6824 Btu/h) (9554 Btu/h)
Injector Marking
079
104
104
130
L.P. Gas
Heat Input
1.0kW
2.0kW
2.0kW
2.7kW
(71.8 g/h)
(143.7 g/h)
(143.7 g/h)
(194.0 g/h)
Injector Marking
051
072
072
083
39
S O N A T A 5 5 G L X a