9. ADMINISTRATOR NUMBER
Once the administrator number is stored in the unit whether programming via dialing in or text
messages can only carry out by this number.
Example:
Program a mobile number as an administrator number via SMS
Mobile number:
0865682554
Command to use *12*1234#74 [Admin number]#
SMS format
* 12*1234#
74
0865682554
#
To delete the Admin number *12*1234#74*#
10. CHCK SIGNAL STRENGTH
When a request for GSM signal strength SMS command is sent to the GSM Opener, the unit
should rely with a signal strength code and service provider name. The code will be between
0~31 means the signal level is from poor to best.
Example:
SMS format
*21*1234#
SMS reply Vodafone Signal Level = 31
【
Signal is very strong
】
11. CHECK RELAY STATUS
You can send SMS
command code
to check relay status.
SMS format *24*1234#
SMS Reply Relay1: [status] (Status = Hold / release / trigger
)
Input 1:[status] , Input 2:[status] (status= high / low)
12. HOW TO RESET THE UNIT WHEN YOU FORGET THE PASSWORD
1. To keep the red button pressed on the PCB
2. Then power up and wait for 5 sec
3. After you see LED 1 and 2
starts to flash which means it’s resetting.
4. Release the r
ed button
THIS MUST BE DONE BEFORE ANY OTHER PROGRAMMING
Page 11