P.000
P.998
0 to 1
0
P.005
P.971
[Cycles]
0 to 9999
0
P.972
[Cycles]
0 to 9999
0
P.973
0 to 1
0
P.010
[Sec]
0 to 9999
P.015
[Sec]
0 to 200
10
P.020
[Ms]
0 to 3000
0
P.025
[Sec]
0 to 20
3
P.143
35 to 100
P.148
35 to 100
P.210
0
P.221
-125 to 125
0
P.222
0 to 2100
P.230
50 to 9999
P.231
-125 to 125
0
P.232
0 to 2100
P.241
[%]
5 to 95
50
P.310
[Hz]
6 to 200
P.320
[Hz]
6 to 200
P.350
[Hz]
6 to 200
P.360
[Hz]
6 to 200
Frequency for automatic opening speed 2
Operating frequency until open limit switch is activated
Parameter Function
Parameter
Display Adj. Range
Factory
Setting
Counter Parameters
Cycle Counter
Indicates the number of previously counted cycles
Reset the cycle counter
After setting this parameter to 1 the current cycle counter is cleared
cycle counter mode
0: Each time the closed limit switch is reached the count goes up by 1
0: Deactivated
1: Warning I.080 shown on display once maintenance counter is reached
Maintenance Counter
Indicates the number of cycles remaining until maintenance is due (if -1 shows it means the counter has not yet been set)
Number of cycles after resetting
Indicates how many cycles are possible after resetting the maintenace counter until the next warning shows
Warning before maintenance counter expiration
Indicates the number of cycles before the maintenance counter expires during which I.080 is displayed
2: Error F.080 shown on display and close in deadman operation only
Speed Parameters
Frequency for automatic opening speed
Operating frequency until open limit switch is activated
1
Obstacle Detection Parameters
Obstacle detection mode
Voltage reduction for open direction
Reducing the value in this parameter increases the sensitivity of the obstacle detection in the open direction
Voltage reduction for close direction
Reducing the value in this parameter increases the sensitivity of the obstacle detection in the close direction
P.480
0 to 2
0: Deactivated
1: Detection of motor overcurrent
2: Detection of incremental change
2
1: Each time the open limit switch is reached the count goes up by 1
2: With each full cycle the count goes up by 1 (going open and closed)
3: With every open command the count goes up by 1
P.981
0 to 3
2
0
Reset the maintenance counter
After setting this parameter to 1 the current maintenance counter is cleared
3: Error F.080 shown on display, open and close in deadman operation only
Frequency for automatic closing speed
Operating frequency until close limit switch is activated
Frequency for automatic closing speed 2
Operating frequency until close limit switch is activated
P.971
0 to 3
Response to maintenance counter
Timer Parameters
0
Auto close timer 1
Will stay in the open position for this length of time before closing
Optional auto close timer
Can be assigned to different inputs for a secondary close time
Open delay timer
Will wait for the set time in milli seconds before opening
Close delay timer
Will wait for the set time in seconds before closing after the auto close timer
Position Parameters
Open and close position calibration
Set to 5 to calibrate the closed (
EIEC
) then open (
EIEO
) positions
Closed position limit correction
This parameter is used to adjust the final closed position in increments, - will close futher, + will close less
Slowdown positions for closing direction
Indicates the position in increments when the gate will start to enter its slow down speed
Open position limit correction
This parameter is used to adjust the final open position in increments, - will open futher, + will open less
Slowdown positions for opening direction
Indicates the position in increments when the gate will start to enter its slow down speed
Pedestrian open position percentage
Indicates the percentage of the overall open position that the gate will open to under a pedestrian open command
Overall travel increments
This parameter shows how many increments there are from the closed to the open position
P.244
0
to
4
Select pedestrian open position
0: No ped
estrian open set, pedestrian open is same as fully open
0 1: Opens to half way point (1/2 of value in P.230)
2: Opens two thirds (2/3 of value in P.230)
3: Pedestrian open position set in deadman
4: Pedestrian open set in percentage (uses P.241)
Содержание PF9700
Страница 13: ...Address Tel Email Web Engineers Sec on Not For End Users Control Panel Overview...
Страница 20: ...Address Tel Email Web...
Страница 21: ...Address Tel Email Web...
Страница 22: ...Address Tel Email Web...
Страница 23: ...Address Tel Email Web...
Страница 24: ...Address Tel Email Web...
Страница 25: ...Address Tel Email Web...
Страница 26: ...Address Tel Email Web...
Страница 27: ...Address Tel Email Web 24v From External PSU Switch to Drop Bolt...