background image

Opera on and Maintenance Manual 

Revision 10.0 2020 

THIS DOCUMENT CONTAINS IMPORTANT 

INFORMATION. IT MUST BE KEPT WITH THE GATE 

AT ALL TIMES. 

Содержание PF9700

Страница 1: ...Opera on and Maintenance Manual Revision 10 0 2020 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION IT MUST BE KEPT WITH THE GATE AT ALL TIMES...

Страница 2: ...site direc on to which the gate was moving Emergency Stop Bu on located on the front of the gate tower this can be used before an incident happens Safe use warnings 1 Do not allow children people with...

Страница 3: ...ly accelerate to full speed un l the intermediate limit is reached at which point the gate will decelerate for the remainder of the travel distance If a safety device is ac vated i e safety edge or ph...

Страница 4: ...ually Only move the gate very slowly no faster than it moves in normal use Your installer will have demonstrated this at handover To return the gate to automa c opera on when the power is restored sim...

Страница 5: ...gate the key switch will give a normal automatic open and close signal If you have two gates working in master and slave mode the key switch will only operate the gate that it is attached to Stop But...

Страница 6: ...terfere with the gate and its safety sensors Keep the photo electric beam covers clean Safety checks These user safety checks should be conducted every few weeks by a responsible adult who has been sh...

Страница 7: ...in a safe condition If the premises are also a workplace there are specific duties under regulation 5 and 18 of the Workplace Health and Safety and Welfare Regulations 1992 Failure to meet duties imp...

Страница 8: ...otocells internal and external Sealing of photocell covers and cable entry Wire termina ons in control panel Sealing of control unit cover and cable entries Condi on of all wiring and junc on boxes Fu...

Страница 9: ...ed safety checks Other insert The following items have been passed to the client Manual release instruc ons Intercom user manual Declara on of Conformity User warnings and residual hazard iden ca on P...

Страница 10: ...nit PFL Swing Gate Drive 3 Phase PFL Drive 3 Phase 550Watts 60Nm Torque 58 RPM 2 3A Nominal Current 35mm Axle Photo beams Witt Argos T Argos R TX RX Through Beam Safe edge ASO 65mm profile Encoder Fei...

Страница 11: ...ork done Company PPM Name Reac ve Signature Date Work done Company PPM Name Reac ve Signature Date Work done Company PPM Name Reac ve Signature Date Work done Company PPM Name Reac ve Signature Date W...

Страница 12: ...nces Safety Household and similar electrical appliances Safety Electromagnetic compatibility EMC Part 6 1 Electromagnetic compatibility EMC Part 6 2 Electromagnetic compatibility EMC Part 6 3 Electrom...

Страница 13: ...Address Tel Email Web Engineers Sec on Not For End Users Control Panel Overview...

Страница 14: ...Swing Gate Base Drawing Base plate Plan View 700 300 1300 700 1300 300 300 300 300 700 1300 700 700 224 224 CABLE ENTRY POSITION 600 300...

Страница 15: ...u drill and chem fix 4x M20 threaded bars into the surface to line up with the fixing holes in the gate tower base plate these have a nut above and below the tower base plate for adjustment alignment...

Страница 16: ...e the open limit switch is reached the count goes up by 1 2 With each full cycle the count goes up by 1 going open and closed 3 With every open command the count goes up by 1 P 981 0 to 3 2 0 Reset th...

Страница 17: ...osition with auto close P 010 position adjustable with P 244 0205 Impulse command N O to fully open position without auto close close on next command 0501 Safety input N C safety reversing when closin...

Страница 18: ...during opening continues to open 28 Safety during opening and closing after releasing during opening continues to open close after fully open 0 No close command 1 Close command only if triggered afte...

Страница 19: ...ayed C 15 Housing tempreature displayed F 29 Display the address of slave module only on master 39 Display the cos phi power factor 40 Display the momentary DC Bus current in percent of maximum contin...

Страница 20: ...Address Tel Email Web...

Страница 21: ...Address Tel Email Web...

Страница 22: ...Address Tel Email Web...

Страница 23: ...Address Tel Email Web...

Страница 24: ...Address Tel Email Web...

Страница 25: ...Address Tel Email Web...

Страница 26: ...Address Tel Email Web...

Страница 27: ...Address Tel Email Web 24v From External PSU Switch to Drop Bolt...

Отзывы: