in
Parking and access control equipment manufactured in the UK
Automatic Raise Arm Barriers
Changing Barrier Handing
Right Handed Barrier
Left Handed Barrier
1.
Ensure Power to Barrier is Isolated
2.
Barrier to be set with pole arm adaptor in down position (Horizontal)
(if not fully down, use hand wind to lower until mechanical sop touches top plate)
(keyway in top shaft should be facing up)
3.
Remove Circlip
4.
Take off ‘Mechanical Stop’
5.
Reverse & Refit ‘Mechanical Stop’
6.
Replace Circlip
7.
Remove ‘Pole Arm Adaptor’ and refit in reversed position
8.
Change Limit Switch Connects
7 to 9 & 9 to 7
8 to 10 & 10 to 8
9.
Reverse Motor Connections
23 to 24 & 24 to 23
10.
Adjust limit strikers to new position
11.
Switch on power and test barrier (keeping hands clear of moving parts)
12.
Finally adjust limit strikers as required for barrier in open & closed position
11
Содержание PF6000
Страница 31: ...29 in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide ...
Страница 32: ...in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide 30 ...
Страница 33: ...31 in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide ...
Страница 34: ...in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide 32 ...
Страница 35: ...33 in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide ...
Страница 36: ...in Parking and access control equipment manufactured in the UK Automatic Raise Arm Barriers Loop Guide 34 ...