background image

6

Owner's Manual:

SMOKEETER® Electronic Air Cleaner

2. Slide components from the cabinet.

NOTE: 

 The SE 40 contains an ionizer and collection cell 
as a one piece assembly known as a unicell.

FIGURE 5

6.2 Cleaning

Major cleaning is confined to the prefilter, ionizer, collection 
cell and the inside cabinet. These should be cleaned 
periodically to assure continued efficiency. Cleaning 
may be required from once a month to once every four 
months depending on the air quality.

NOTE:  

The carbon filter cannot be cleaned and needs 
to be replaced as required.

1. Disconnect power to unit and remove components.
2. The ionizer, collection cell/unicell and prefilter can be 

cleaned by soaking in a hot solution of SMOKEETER 
brand detergent for 30 to 60 minutes. If possible,  
agitate the solution to aid in dirt removal. If agitation  
is not possible, soaking time should be increased.

C A U T I O N

DO NOT USE TEMPERATURE EXCEEDING 160°F AND DO 

NOT STEAM CLEAN AS THIS MAY CAUSE PERMANENT 

DAMAGE TO THE COMPONENTS. IF DETERGENT OTHER 

THAN SMOKEETER BRAND IS USED, CARE MUST BE 

TAKEN TO ASSURE THAT IT CONTAINS AN ALUMINUM 

INHIBITOR SO THAT IT DOES NOT ATTACK THE ALUMINUM 

COMPONENTS. BE SURE TO FOLLOW MANUFACTURER’S 

CLEANING INSTRUCTIONS.

3. Remove the components from the detergent bath and 

immediately flush away any residue and rinse thoroughly 
with clear hot (less 160°F) water. Shake off excess 
water and let components dry for 30 to 60 minutes. 
Set the cell so that its plates are in a vertical position 
for drainage.

4. Vacuum clean the interior of the cabinet and clean  

off all electrical connections before reinstalling  
the components.

5. Reinstall the components into the cabinet.
6. Apply power to unit and confirm indicator light  

is illuminated.

Содержание SMOKEETER SE-40

Страница 1: ...Owner s Manual Commercial Air Cleaner Smokeeter Models SE 40 Variable Speed SE 50 3 Speed...

Страница 2: ...contacting Parker Hannifin UNIT ORDER ______________________________________________________________________________________ UNIT MODEL ________________________________________________________________...

Страница 3: ...h if not avoided may result in property damage Important Safety Instructions WARNING To reduce the risk of fire electric shock or injury when using the air cleaner follow these basic precautions Use t...

Страница 4: ..._________________________________________7 7 1 COMPONENT FUNCTION________________________________________________________________________7 7 2 HOW THE HIGH VOLTAGE IS SUPPLIED TO THE COMPONENTS_______...

Страница 5: ...ipping 120 lbs 54 kg DIMENSIONS Height Width Length 12 7 8 21 40 33 cm 53 cm 102 cm MODEL SE 40 CFM is variable POWER REQUIREMENTS 115 VAC 60 HZ 8 4 Amps max POWER CONSUMPTION 900 Watts max AIR HANDLI...

Страница 6: ...2 Owner s Manual SMOKEETER Electronic Air Cleaner DIMENSIONS SE 40 SE 50...

Страница 7: ...nd attract the charged particles removing them from the air The plates are alternately charged positive and ground The positive plates repel the particles while the ground plates attract them yielding...

Страница 8: ...vided Install two 3 8 16 x 1 1 4 leveling screws in the bottom outside holes Refer to Figure 2 Place the unit on a lifting device Position the lifting device under the wall mounting cleat Raise the un...

Страница 9: ...The noise should cease after a few minutes of operation 6 0 CLEANING CAUTION SERVICING THIS PRODUCT FOR PURPOSES OTHER THAN ROUTINE CLEANING OF THE COLLECTION COMPONENTS SHOULD BE PERFORMED BY TRAINED...

Страница 10: ...te the solution to aid in dirt removal If agitation is not possible soaking time should be increased CAUTION DO NOT USE TEMPERATURE EXCEEDING 160 F AND DO NOT STEAM CLEAN AS THIS MAY CAUSE PERMANENT D...

Страница 11: ...lates are alternately charged with a nominal 5 500 volts DC positive The field between the plates forces the charged particles to the ground plates removing them from the airstream NOTE The SE 40 cont...

Страница 12: ...emove the components from the cabinet 2 Engage the safety interlock switch and measure the output from the ionizer terminal of the power supply by placing the probe s tip on the ionizer high voltage c...

Страница 13: ...owly rise to infinity NOTE This indicates that the capacitor will charge and discharge 6 If the capacitor does not charge replace the capacitor FIGURE 9 8 0 PARTS ORDERING Replacement parts can be ord...

Страница 14: ...2 Engage safety interlock switch 3 Replace safety interlock switch 4 Replace control switch D Motor operates on low or high speed only 1 Control switch defective 1 Replace control switch E Poor air qu...

Страница 15: ...11 Owner s Manual SMOKEETER Electronic Air Cleaner 10 0 llustrated Parts SE 40 Final Assembly...

Страница 16: ...7 0013 INSULATOR 2 15 36 0014 CONTACT SPRING 2 16 36 0077 GROUND SPRING 1 17 10 2574 BLOWER SUPPORT 1 20 30 0031 SCREW OVAL HD 8 31 X 3 4 L 2 21 30 0335 SCREW HEX HD 8 32 X 3 8 L 4 22 30 0206 SCR FL H...

Страница 17: ...13 Owner s Manual SMOKEETER Electronic Air Cleaner SE 40 UNICELLULAR ASSEMBLY 02 1321...

Страница 18: ...PAN HEAD SCREW 8 11 30 0081 8 FLAT WASHER 4 12 30 0520 10 32 X 1 2 HEX HEAD SCREW 4 13 30 0500 10 32 HEX NUT LOCKING 4 14 02 1318 IONIZER TO CONTACT WIRE ASSEMBLY 1 15 35 0174 CELL HIGH VOLTAGE CONTAC...

Страница 19: ...Motor Blower Assembly 02 2544 Item No Part No Description Quantity 1 32 0083 BLOWER DIRECT DRIVE 1 2 02 1327 MOTOR 1 3 20 0569 CAPACITOR 1 4 20 1298 CAPACITOR STRAP 1 5 30 0335 SCREW HEX HD 8 32 X 1...

Страница 20: ...LOT AMBER 1 4 20 0560 SWITCH INTLK DP NO 1 5 30 0164 RETAINER SOUTHCO 1 6 30 0165 SCREW WING HEAD 1 7 30 0301 SCREW PAN HD 6 32 X 1 1 4 L 2 8 30 0038 LOCKWASHER 6 DOUBLE 1 9 30 0345 TINNERMAN NUT 6 IN...

Страница 21: ...17 Owner s Manual SMOKEETER Electronic Air Cleaner SE 50 FINAL ASSEMBLY...

Страница 22: ...LY 1 10 02 0086 COLLECTION CELL 1 11 33 0007 CARBON FILTER 1 12 10 2606 BLOWER SUPPORT ANGLE 1 13 10 2799 HANGING BRACKET 2 14 20 2922 CORD IEC 90 DEG 1 15 20 2921 IEC 320 POWER INLET 1 16 36 0077 SPR...

Страница 23: ...1 30 0030 1 4 20 LOCK NUT 4 2 30 0049 1 4 FLAT WASHER 4 3 35 0027 ROD 2 4 10 0465 CORNER CHANNEL 2 5 37 0004 INSULATOR 4 6 10 0570 IONIZER WIRE SUPPORT RAILS 2 7 30 0142 8 32 X 1 2 PAN HEAD SCREW 8 8...

Страница 24: ...No Description Quantity 1 30 0030 1 4 20 LOCK NUT 16 2 37 0008 INSULATOR 8 3 A 10 0564 HANDLE 1 3 B 10 0559 COVER PLATE HANDLE 1 4 10 0348 END PLATE 2 5 41 0330 WARNING LABEL 1 6 10 0157 HOT CELL PLAT...

Страница 25: ...CH CONTROL 3 SPEED 1 3 20 0229 LIGHT PILOT AMBER 1 4 20 0560 SWITCH INTLK DP NO 1 5 30 0164 RETAINER SOUTHCO 1 6 30 0165 SCREW WING HEAD 1 7 30 0301 SCREW PAN HD 6 32 X 1 1 4 L 2 8 30 0038 LOCKWASHER...

Страница 26: ...sembly 02 10650 0001 Item No Part No Description Quantity 1 32 0085 BLOWER DIRECT DRIVE 10 10 1 2 22 10018 0001 MOTOR 5 SPEED 1 3 20 10090 0001 CAPACITOR 5NF 1 4 20 1298 CAPACITOR MOUNTING BRACKET 1 5...

Страница 27: ...23 Owner s Manual SMOKEETER Electronic Air Cleaner 11 0 Wiring Diagram MODEL SE 40 41 2488 MODEL SE 50 41 10028...

Страница 28: ...rmal use or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclusive remedy for...

Страница 29: ...Description of troubleshooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investiga tion and provide full information an...

Страница 30: ...____________________________________________________ ___________________________________________________________________________ _______________________________________________________________________...

Страница 31: ...____________________________________________________ ___________________________________________________________________________ _______________________________________________________________________...

Страница 32: ...Division EMEA Dewsbury United Kingdom 44 0 1924 487 037 Gas Separation Filtration Division EMEA Team Valley United Kingdom 44 0 191 402 9000 Gas Turbine Filtration Division Alton United Kingdom 44 0...

Отзывы: