Service/Spare Parts Manual
Series V14
MSG30-5510-M1/UK
38
Parker Hannifin
Pump & Motor Division Europe
Trollhättan, Sweden
Test procedure
Use a test stand that supplies a flow of about 30 l/min.
and pressures of up to 300 bar.
A secondary flow of 3 – 5 l/min. at a pressure of 25 bar
is required to supply low pressure for externally sup-
plied controls.
EP control requires an amplifier supplying correct cur-
rent according to specification.
Test
1. Fill housing with hydraulicfluid and start the pump in
thetest stand.
2. Increase the pressurewith the restrictor valve onthe
return line. Max allowedpressure is 150 bar/2150 psi.
3. Check the drain flow andcompare with the table.
Pump
V14
Max 150 bar / 2150 psi
Max 220 bar / 3100 psi
~ 30 l/min
Servo oil
Servolja
Drain flow (l/min.),
control not activated.
V14-110, -160
4.0
Test procedure