22
PSVG-IQAN-C2E1M2W1U1
Power Control Input
The PVSG-IQAN has 1 power control input. The power control input
activates the unit or shuts it down.
Damage to equipment!
Do not connect inputs directly to
unprotected inductive loads such as solenoids or relay coils, as
these can produce high voltage spikes that may damage the
PVSG-IQAN. If an inductive load must be connected to an input,
use protective circuitry such as a diode or transorb.
6.1. Power Control input capabilities
The PVSG-IQAN has an active-high power control digital input that must
be activated to power up the unit.
The power control digital input activates the PVSG-IQAN when switched
high, and begin a controlled shutdown sequence (if applicable) and de-
activates the module when power is removed.
It is recommended that this input be controlled by the vehicle ignition
switch.
6. Power Control Input