isysNet Relay Output Module, Series A (PSSTR4M12A) 

E109P

5

Wire the Relay Output Module

Following are wiring instructions for the relay output module.

Make sure all connectors and caps are securely tightened to 
properly seal the connections against leaks and maintain IP67 
requirements.

!

ATTENTION

(view into connector)

Pin 1 - 24VDC
Pin 2 - Output 0B (M12-A) 

Pin 4 - Output 0A (M12-A) 

 

  Output 1B (M12-B) 

 

  Output 1A (M12-B) 

 

  Output 2B (M12-C) 

 

  Output 2A (M12-C) 

 

  Output 3B (M12-D) 

 

  Output 3A (M12-D)

Pin 3 - Common 

Pin 5 - No Connect

PSSTR4M12A

PSSTR4M12A is rated for 5-28.8 VDC only.  Do not connect it 
to an AC power source.

!

WARNING

Communicate With Your Module

I/O messages are sent to (consumed) and received from (produced) 
the  I/O  module. These  messages  are  mapped  into  the  processor’s 
memory.  The I/O relay output module consumes 1 byte of output data 
(scanner Tx - status).  It does not produce data (scanner Rx).

Default Data Map for the Relay Output Modules 

PSSTR4M12A

Message Size: 1 Byte

 

0

Consumes 

Not Used 

Ch3  Ch2  Ch1  Ch0  Output 

(Scanner Tx) 

 

 

 

 

 

State 

Where:  0 = OFF, 1 = ON

EDS File Requirements

The EDS file is available online at www.parker.com/pneu/isysnet.

Load Powered by Internal Power Bus

Load Powered by External Power Bus

Sourcing

Common

3

Output B

2

Output A

4

24VDC

1

Load

+

Sinking

Common

3

Output B

2

Output A

4

24VDC

1

Load

+

Power

Supply

+

Sourcing

Common

3

Output B

2

Output A

4

24VDC

1

Load

+

Power

Supply

+

Sinking

Common

3

Output B

2

Output A

4

24VDC

1

Load

+

Содержание PSSTR4M12A

Страница 1: ...hat all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and prici...

Страница 2: ...s Attentions help you Identify a Hazard Avoid a Hazard Recognize the Consequence SHOCK HAZARD Labels may be located on or inside the equipment to alert people that dangerous voltage may be present BUR...

Страница 3: ...and Tap for M6 Screw Ground Lug Connection Latching Mechanism Mounting Base Keyswitch Set to position 7 for the PSSTR4M12A relay output modules Install the Mounting Base as Follows 1 Lay out the requ...

Страница 4: ...odule down until it engages the latching mechanism You will hear a clicking sound when the module is properly engaged The locking mechanism will lock the module to the base Remove the Relay Output Mod...

Страница 5: ...ur Module I O messages are sent to consumed and received from produced the I O module These messages are mapped into the processor s memory The I O relay output module consumes 1 byte of output data s...

Страница 6: ...e that the PSSTR4M12A is now under the I O configuration Add Relay Output Module to RSLogix 5000 I O Configuration To add your relay output module to RSLogix 5000 I O configuration follow these steps...

Страница 7: ...cation faulted device the device has detected a network access error and is in communication faulted state Device has received and accepted an Identity Communication Faulted Request long protocol mess...

Страница 8: ...Test Nb Operating Thermal Shock 20 to 60 C 4 to 140 F Storage Temperature IEC 60068 2 1 Test Ab Un packaged Non operating Cold IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat 40 to 85 C 40 to...

Отзывы: