Parker PSSTR4M12A Скачать руководство пользователя страница 3

isysNet Relay Output Module, Series A (PSSTR4M12A) 

E109P

3

Mount the I/O Base

To  mount  the  I/O  base  on  a  wall  or  panel,  use  the  screw  holes 
provided in the base.

A mounting illustration for the base with an adapter is shown below.

Inches

(mm)

Adapter

2.0

(50)

2.0

(50)

1.9

(47.2)

4.02

(102)

1.81

(46)

4.32

(109.8)

5.39

(137.0)

Drill and Tap

for M4 Screw

2.39

(60.7)

3.02

(76.6)

3.13

(79.4)

5.98*

(151.9)

0.87

(22)

Drill and Tap

for M6 Screw

Ground Lug
Connection

Latching Mechanism

Mounting Base

  Keyswitch-
  Set to position 7
  for the PSSTR4M12A
  relay output
  modules

Install the Mounting Base as Follows:

  1. Lay  out  the  required  points  as  shown  above  in  the  drilling 

dimension drawing.

  2. Drill  the  necessary  holes  for  #8  (M4)  machine  or  self-tapping 

screws.

  3. Mount the base using #8 (M4) screws.
  4. Ground the system using the ground lug connection.  (The ground 

lug connection is also a mounting hole.)

* Depending on the type and number of manifolds, this dimension 

may vary.  Refer to Catalog 0600P-# for additional information.

Содержание PSSTR4M12A

Страница 1: ...hat all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and prici...

Страница 2: ...s Attentions help you Identify a Hazard Avoid a Hazard Recognize the Consequence SHOCK HAZARD Labels may be located on or inside the equipment to alert people that dangerous voltage may be present BUR...

Страница 3: ...and Tap for M6 Screw Ground Lug Connection Latching Mechanism Mounting Base Keyswitch Set to position 7 for the PSSTR4M12A relay output modules Install the Mounting Base as Follows 1 Lay out the requ...

Страница 4: ...odule down until it engages the latching mechanism You will hear a clicking sound when the module is properly engaged The locking mechanism will lock the module to the base Remove the Relay Output Mod...

Страница 5: ...ur Module I O messages are sent to consumed and received from produced the I O module These messages are mapped into the processor s memory The I O relay output module consumes 1 byte of output data s...

Страница 6: ...e that the PSSTR4M12A is now under the I O configuration Add Relay Output Module to RSLogix 5000 I O Configuration To add your relay output module to RSLogix 5000 I O configuration follow these steps...

Страница 7: ...cation faulted device the device has detected a network access error and is in communication faulted state Device has received and accepted an Identity Communication Faulted Request long protocol mess...

Страница 8: ...Test Nb Operating Thermal Shock 20 to 60 C 4 to 140 F Storage Temperature IEC 60068 2 1 Test Ab Un packaged Non operating Cold IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat 40 to 85 C 40 to...

Отзывы: