![Parker PSSTR4M12A Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/parker/psstr4m12a/psstr4m12a_installation-and-service-instructions-manual_3817231003.webp)
isysNet Relay Output Module, Series A (PSSTR4M12A)
E109P
3
Mount the I/O Base
To mount the I/O base on a wall or panel, use the screw holes
provided in the base.
A mounting illustration for the base with an adapter is shown below.
Inches
(mm)
Adapter
2.0
(50)
2.0
(50)
1.9
(47.2)
4.02
(102)
1.81
(46)
4.32
(109.8)
5.39
(137.0)
Drill and Tap
for M4 Screw
2.39
(60.7)
3.02
(76.6)
3.13
(79.4)
5.98*
(151.9)
0.87
(22)
Drill and Tap
for M6 Screw
Ground Lug
Connection
Latching Mechanism
Mounting Base
Keyswitch-
Set to position 7
for the PSSTR4M12A
relay output
modules
Install the Mounting Base as Follows:
1. Lay out the required points as shown above in the drilling
dimension drawing.
2. Drill the necessary holes for #8 (M4) machine or self-tapping
screws.
3. Mount the base using #8 (M4) screws.
4. Ground the system using the ground lug connection. (The ground
lug connection is also a mounting hole.)
* Depending on the type and number of manifolds, this dimension