background image

CTC Parker Automation

A3-06057-102

P C 9 / P 9   C h a s s i s   F a n   R e p l a c e m e n t

Introduction

These instructions explain how to replace the fans that cool the configura-
tion bay and the maintenance compartment in the PC9 Industrial PC or the 
P9 PowerStation. They include steps for disassembling the unit, removing 
an old fan, installing a new fan, and reassembling the unit.

Warning

For safety reasons, the unit should be opened only by qualified 
service personnel.

Warning

Be sure to observe electrostatic discharge (ESD) precautions 
while working inside the unit.

To complete this procedure, you will need the following items:

Replacement Fan for PC9/P9 (FAN-9000)

Phillips-head screwdriver

5/16” nut driver

Disassembling the Unit

To disassemble the unit, follow these steps:

1. Turn off the unit.

2. Disconnect the unit from the power source.

3. Disconnect all cables attached to the unit.

4. Remove the two screws securing the backshell to the faceplate as-

sembly, as shown in Figure 1 on page 2.

Содержание PC9

Страница 1: ...ns the unit should be opened only by qualified service personnel Warning Be sure to observe electrostatic discharge ESD precautions while working inside the unit To complete this procedure you will ne...

Страница 2: ...Figure 2 Then go to step 8 Figure 2 Disconnecting PC9 Cables a Detach the monitor ribbon cable from its connection at the center of the monitor frame push back the locking clamps from either side of...

Страница 3: ...ance compartment c Detach the backlight cable from its connection on the monitor card press down on the small tab on the lower half of the connector and pull the cable out 8 Remove the safety bracket...

Страница 4: ...ifting the backshell grasp it from the outside If you have a P9 be careful not to touch the monitor card located inside the top of the maintenance compartment The monitor card is shown in Figure 3 on...

Страница 5: ...de of the maintenance compartment as shown in Figure 6 Then go to step 4 Figure 6 Maintenance Compartment Fan 2 If you are replacing the configuration bay fan locate the fan at the left side of the co...

Страница 6: ...nance compartment fan make sure that the arrow on the side of the fan is pointing toward the inside of the unit Warning You can mount the new fan in any orientation However make sure that the arrow on...

Страница 7: ...tor card located inside the top of the maintenance compartment The monitor card is shown in Figure 3 on page 3 4 Re attach the backlight cable touchscreen cable if necessary and monitor cable if you h...

Страница 8: ...PC9 P9 Chassis Fan Replacement 8 CTC Parker Automation...

Отзывы: