Parker Hannifin Corporation
Pneumatic Division Europe
www.parker.com/pde
41
Integration Guide
Rockwell 1734-OB8S or 1734-OBV2S
FRL-SIF-120
_EU
Parker Pneumatic
With this schematic it is possible to achieve up to Cat 4 PL e if properly implemented.
With this schematic it is possible to achieve up to Cat 4 PL e if properly implemented.
Rockwell 1734-OB8S with 1734-IB8S wiring schematic to interface to Safety Exhaust Valve
Rockwell 1734-OBV2S with 1734-IB8S wiring schematic to interface to Safety Exhaust Valve
SOL 1
O0 (blk)
O1 (wht)
COM (blu)
T1M (blk)
I1 (gry)
T0 (wht)
I0 (brn)
COM (blu)
SW2
SW1
SOL 2
4
4 1
To 1734-OB8S
To 1734-IB8S
0
0
6
1
7
SOL 1
O0 (blk)
O1 (wht)
T1M (blk)
I1 (gry)
T0 (wht)
I0 (brn)
COM (blu)
SW2
SW1
SOL 2
4
O1
To 1734-OBV2S
To 1734-IB8S
O0
0
6
1
7
M12 Pinouts for P33
M12 Pinouts for P33
A
5
1
3
4
2
Sol 2
Sol 1
+
-
+
1 Brown
2 White
3 Blue
4 Black
5 Grey
5
1
3
4
2
SW
1
SW
2
B
+
+
-
1 Brown
2 White
3 Blue
4 Black
5 Grey
5
1
3
4
2
SW
1
SW
2
B
+
+
-
5
1
3
4
2
Sol 1 Sol 2
D
+
-
1734-IB8S
1734-IB8S
1734-OB8S
1734-OBV2S
Module Configuration
Controller
Configuration
Parameter Name
Configuration
Setting
Controller
Configuration
Parameter Name
Configuration
Setting
Safety Output 0
Safety Output 0 Point Mode
Safety Pulse Test
Safety Input 0
Safety Input Channel Mode
Standard
Point Operation Type
Dual-channel
Point Operation Type
Single-channel
Safety Output 1
Safety Output 1 Point Mode
Safety Pulse Test
Safety Input 1
Safety Input Channel Mode
Standard
Module Configuration
Controller
Configuration
Parameter Name
Configuration
Setting
Controller
Configuration
Parameter Name
Configuration
Setting
Safety Output 0
Safety Output 0 Point Mode
Safety Pulse Test
Safety Input 0
Safety Input Channel Mode
Standard
Safety Output 1
Safety Output 1 Point Mode
Safety Pulse Test
Safety Input 1
Safety Input Channel Mode
Standard