Parker P2M Node 24 DO Скачать руководство пользователя страница 8

Page 8 /15

P2M2HBVT12400

User Manual

30060921401W05 

February 2018

Pneumatic Division

27031 Evreux - France

Green / Red LED

Green LEDs

Red LED

Green / Red LED

LED

Status

Description

Troubleshooting

LED

Status

Description

Troubleshooting

LED

Status

Description

Troubleshooting

LED

Status

Description

Troubleshooting

OFF

Logic lines
not powered

Check power 
supply (pin's 2 & 4
on Power M-12)

OFF

Not link, no 
activity

Check 
connection to 
the Network

OFF

No error

N/A

OFF

Initialization
Power supply 
missing

N/A
Check power 
supply

ON

GREEN

Logic Power 
OK

N/A

ON

GREEN

Link sensed, no 
activity

N/A

Blinking

Invalid 
configuration

Check register 
or object 
settings

ON

GREEN

Operational

N/A

ON 

RED

Presence of 
any fault 
requiring 
acknowledge

Fix the issue and 
acknowledge error/ 
power cycle the 
module

Blinking 

GREEN

Link sensed, 
activity

N/A

Single 

Flash

Unsolicited 
state change

Reset module 
(power OFF/ON)

Blinking

GREEN

Pre-operational N/A

Blinking

G/R

Firmware 
Version 
error

Contact technical 
support or change 
the module

Double 

Flash

Sync manager 
watchdog 
timeout

Reset module 
(power OFF/ON)

Single 

Flash

GREEN

Safe-
operational

N/A

ON

Allocation 
controller failure

Reset module 
(power OFF/ON)
If also RUN LED 
turns RED, change 
the module

Flashing

GREEN

BOOT

N/A

Flicker

Booting error 
detected

Firmware 
exception
Change the 
module

RED

Fatal event

If also ERR turns 
RED, change the 
module

Red LED

LED

Status

Description

Troubleshooting

OFF

Standard mode
(No error active)

N/A

ON

RED

One (or more)  

active “o

utputs 

stage

failure”

Check diagnostic 
message through
the Network and 
relative 
troubleshooting

Local Visual Diagnostic

The P2M Node 24DO module offers local diagnostics through 6

LED’s

status with interpretation described in

the table below:

NOTE:

Errors caused by solenoid(s) must be fixed first and then the error must be acknowledged by either one of the following actions:

switching OFF/ON Auxiliary power supply (once error is fixed)

sending the

“Acknowledge Error”

command

**SEE Manufacturing Specific Object

“System Command”

Diagnostic through network via Object

“Module

Error

Input”

The P2M Node 24DO module offers diagnostic data transmitted to the PLC as Process Data Input or via the Manufacturing Specific
Object

“Module

Error

Input”

:

Byte 0

Diag 7 . . . . . . . . . . . . . Diag 0

Byte 1

Reserved

Bit #

Error Name

Error Description

Diag 0

Ack-Required

Set if any major fault active. Outputs are switched OFF and acknowledge is required to restart 
the module to normal operation

Diag 1

Auxiliary Voltage Warning

Set if Auxiliary Voltage in warning range. Module keeps normal operation

Diag 2

Auxiliary Voltage Failure

Auxiliary Voltage in Error range. Outputs are switched OFF and acknowledge is required to 
restart the module to normal operation

Diag 3

Temperature Warning

Set if a temperature increase above warning levels is detected by the output drivers

Diag 4

Output Driver Channel Error

Set if a major fault is detected at the output stage 

solenoid short circuit. Outputs are 

switched OFF and acknowledge is required to restart the module to normal operation

Diag 5

Module Error

Set if an internal communication error is active. Depending on the fault the module might 
require acknowledgment. 

Diag 6

Outputs Stage Not Available

Set if auxiliary power is missing. No acknowledge is required

Diag 7-15

Reserved 

These bits will be always set as 0

Index

Name

Data Type

Access

0x2009

Module Error Input

UINT

Read

Содержание P2M Node 24 DO

Страница 1: ...USER MANUAL P2M Node 24 DO P2M2HBVT12400 ...

Страница 2: ...e 2 15 P2M2HBVT12400 User Manual 30060921401W05 February 2018 Pneumatic Division 27031 Evreux France EtherCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany ...

Страница 3: ... Power Management 09 Power supply diagnostic through LED 09 Power supply diagnostic thought Network 09 Auxiliary voltage reading 09 Auxiliary power supply range adjustment Rotary Switches 10 P2M Node 24 DO Configuration File 10 Mapping of I O Process Data 10 Process Output Data Mapping 10 Process Input Data Mapping 10 Manufacturer Specific Objects 11 Process Data Outputs 11 Manufacturing Specific ...

Страница 4: ...O 15407 2 and 5599 2 Valves Series Depending on the valve series the module is connected to it can control up to 24 pilot solenoid valves as shown on the illustration below For details on appropriate valve adaptor to use please refer to the respective valve series technical catalogue and instruction sheets Module assembly disassembly 2 4 3 5 To disassemble follow steps backward 1 Product general o...

Страница 5: ...o IEC 60068 2 6 2007 EMC According to EN 55011 EN 61000 4 2 up to 4 6 Auxiliary power consumption calculation Depending on the valve range the module is connected to the pilot solenoids differ in power consumption In order to determine the minimum required power to supply the table below may be used Technical Data P2M Node 24DO electrical specifications NOTE it is recommended that the total output...

Страница 6: ...lve Series can handle up to 24 pilot solenoid valves Addressing is as shown below Byte 1 EV08 EV01 PLC Process outputs data mapping Byte 2 EV16 EV09 Byte 3 EV24 EV20 EV19 EV17 Byte 3 Bits 3 to 7 are not connected to valves with Moduflex Valve Range Byte 1 EV08 EV01 0 7 PLC Process outputs data mapping Byte 2 EV16 EV09 Byte 3 EV24 EV17 EV01 EV02 EV03 EV04 EV05 EV06 EV07 EV08 EV09 EV10 EV11 EV12 EV1...

Страница 7: ...dard Female M12 D Coded connectors 4 pins Auxiliary Power Supply Standard Male M12 A Coded connector 4 pins Use of standard manufactured cables available from usual electrical supplier is recommended Out In Power The P2M Node 24DO Auxiliary Power for valves can be supplied from a SAFE 24Vdc auxiliary source in PP or PM mode as well as from Output Switching Signals Device Failsafe Digital Outputs O...

Страница 8: ...l Visual Diagnostic The P2M Node 24DO module offers local diagnostics through 6 LED s status with interpretation described in the table below NOTE Errors caused by solenoid s must be fixed first and then the error must be acknowledged by either one of the following actions switching OFF ON Auxiliary power supply once error is fixed sending the Acknowledge Error command SEE Manufacturing Specific O...

Страница 9: ...ly diagnostic through Network and Process Data mapping Index Data Type Access Name Min Value Max Value Default 0x200B UINT Read Write AUX Voltage Warning Low Limit 18000 24000 20000 0x200C UINT Read Write AUX Voltage Warning High Limit 24000 28500 26400 Auxiliary power supply range adjustment Normal auxiliary power supply voltage range is set by default as 20 0V Aux power supply 26 4V The low and ...

Страница 10: ...ss Output Data Mapping RPDO Byte Mapped Object Index Sub Index Name 0 0x2008 0x00 System Commands 1 0x2001 0x01 Solenoids Channel 1 to 8 2 0x2001 0x02 Solenoids Channel 9 to 16 3 0x2001 0x03 Solenoids Channel 17 to 24 Process Input Data Mapping TPDO Byte Mapped Object Index Sub Index Name 0 0x2009 0x00 Module Error Input LSB 1 Module Error Input MSB 2 0x2006 0x01 Channel Error Channel 1 to 8 4 0x2...

Страница 11: ...RO Module Error 0x2006 0x00 USINT RO Number of Entries 0x03 0x2006 0x01 USINT RO Channel Error Channel 1 to 8 0x2006 0x02 USINT RO Channel Error Channel 9 to 16 0x2006 0x03 USINT RO Channel Error Channel 17 to 24 0x2007 0x00 UINT RO Module Info Flags 0x2008 0x00 USINT RW System Commands 0x2009 0x00 UINT RO Module Error Input 0x200B 0x00 UINT RW AUX Voltage Warning Limit Low 0x200C 0x00 UINT RW AUX...

Страница 12: ...he Object Command Value Command Name Description 0x01 Leave Failsafe State Acknowledge Error This command allows the module to leave failsafe state acknowledge error Meaning that if no error is pending at the time the Leave Failsafe State command is executed then the device returns to normal operation and the outputs are set according to process data If Failsafe state is reached then it is not aut...

Страница 13: ... Specific Object Manufacturer Specific Object AUX Voltage Warning Low Limit This Manufacturing Specific Object contains the value for the AUX Voltage Warning Low Limit in millivolts i e the low AUX Voltage value that will trigger the AUX Voltage Warning diagnostic Values shown in mV Manufacturer Specific Object AUX Voltage Warning High Limit This Manufacturing Specific Object contains the value fo...

Страница 14: ...dule states and faults errors that might affect the module The faults identified in the module error flag are not recoverable therefore a power cycle is required to clear them If the faults are still present following a power cycle the module has to be replaced The message headers and flag definitions associated with each bit in the Manufacturing Specific Object are detailed in the table below Man...

Страница 15: ...range 2 AUX Voltage Error Set if the Auxiliary Voltage is outside Warning and within Error range The outputs are switched off and an acknowledge is required to restart the module 3 Temperature Warning Set if a temperature warning in one of the output driver chips is detected Outputs are switched off and an acknowledge is required to restart the module 4 Output Driver Channel Error Set if an over c...

Страница 16: ...acturing France SAS Pneumatic Division Europe Parc d Activités de la Forêt BP 3124 534 rue Henri Becquerel 27031 EVREUX CEDEX FRANCE P2M Node 24DO User Manual UK30060921401W05 Release February 2019 www parker com pde P2M_IE ...

Отзывы: