Page 8 /15
P2M2HBVT12400
User Manual
30060921401W05
February 2018
Pneumatic Division
27031 Evreux - France
Green / Red LED
Green LEDs
Red LED
Green / Red LED
LED
Status
Description
Troubleshooting
LED
Status
Description
Troubleshooting
LED
Status
Description
Troubleshooting
LED
Status
Description
Troubleshooting
OFF
Logic lines
not powered
Check power
supply (pin's 2 & 4
on Power M-12)
OFF
Not link, no
activity
Check
connection to
the Network
OFF
No error
N/A
OFF
Initialization
Power supply
missing
N/A
Check power
supply
ON
GREEN
Logic Power
OK
N/A
ON
GREEN
Link sensed, no
activity
N/A
Blinking
Invalid
configuration
Check register
or object
settings
ON
GREEN
Operational
N/A
ON
RED
Presence of
any fault
requiring
acknowledge
Fix the issue and
acknowledge error/
power cycle the
module
Blinking
GREEN
Link sensed,
activity
N/A
Single
Flash
Unsolicited
state change
Reset module
(power OFF/ON)
Blinking
GREEN
Pre-operational N/A
Blinking
G/R
Firmware
Version
error
Contact technical
support or change
the module
Double
Flash
Sync manager
watchdog
timeout
Reset module
(power OFF/ON)
Single
Flash
GREEN
Safe-
operational
N/A
ON
Allocation
controller failure
Reset module
(power OFF/ON)
If also RUN LED
turns RED, change
the module
Flashing
GREEN
BOOT
N/A
Flicker
Booting error
detected
Firmware
exception
Change the
module
RED
Fatal event
If also ERR turns
RED, change the
module
Red LED
LED
Status
Description
Troubleshooting
OFF
Standard mode
(No error active)
N/A
ON
RED
One (or more)
active “o
utputs
stage
failure”
Check diagnostic
message through
the Network and
relative
troubleshooting
Local Visual Diagnostic
The P2M Node 24DO module offers local diagnostics through 6
LED’s
status with interpretation described in
the table below:
NOTE:
Errors caused by solenoid(s) must be fixed first and then the error must be acknowledged by either one of the following actions:
•
switching OFF/ON Auxiliary power supply (once error is fixed)
•
sending the
“Acknowledge Error”
command
**SEE Manufacturing Specific Object
“System Command”
Diagnostic through network via Object
“Module
Error
Input”
The P2M Node 24DO module offers diagnostic data transmitted to the PLC as Process Data Input or via the Manufacturing Specific
Object
“Module
Error
Input”
:
Byte 0
Diag 7 . . . . . . . . . . . . . Diag 0
Byte 1
Reserved
Bit #
Error Name
Error Description
Diag 0
Ack-Required
Set if any major fault active. Outputs are switched OFF and acknowledge is required to restart
the module to normal operation
Diag 1
Auxiliary Voltage Warning
Set if Auxiliary Voltage in warning range. Module keeps normal operation
Diag 2
Auxiliary Voltage Failure
Auxiliary Voltage in Error range. Outputs are switched OFF and acknowledge is required to
restart the module to normal operation
Diag 3
Temperature Warning
Set if a temperature increase above warning levels is detected by the output drivers
Diag 4
Output Driver Channel Error
Set if a major fault is detected at the output stage
–
solenoid short circuit. Outputs are
switched OFF and acknowledge is required to restart the module to normal operation
Diag 5
Module Error
Set if an internal communication error is active. Depending on the fault the module might
require acknowledgment.
Diag 6
Outputs Stage Not Available
Set if auxiliary power is missing. No acknowledge is required
Diag 7-15
Reserved
These bits will be always set as 0
Index
Name
Data Type
Access
0x2009
Module Error Input
UINT
Read