background image

MAINTENANCE INTERVALS

09

OIL-X Compressed Air Filter - User Guide. ©2019.

To ensure optimal filter performance the OIL-X Grade AO and OIL-X Grade AA coalescing and dry particulate filter elements require 
changing every 12 months (8736 hours) along with the automatic float drain.

Unlike coalescing and dry particulate filter elements which are changed annually to guarantee compressed air quality, the lifetime of an 
adsorption filter element / cartridge can be attributed to various factors and will require more frequent changes. Factors affecting the 
lifetime of adsorption filters are:

Oil vapour concentration

The higher the inlet concentration of oil vapour, the faster the adsorption material capacity will be used, resulting in reduced adsorption 
filter element / cartridge lifetime.

Bulk oil 

Adsorption filters are designed only to reduce oil vapours and odours, not liquid oil or oil aerosols. Poorly maintained or non-existent 
pre-filtration (coalescing filters) will cause the adsorption filter capacity to be used quickly resulting in reduced adsorption filter element / 
cartridge lifetime.

Temperature

Oil vapour content increases exponentially to inlet temperature, reducing adsorption filter element / cartridge lifetime. Additionally, as 
temperature increases, the adsorption capacity of the adsorbent material decreases, again reducing adsorption filter element / cartridge 
lifetime.

Relative Humidity or Dewpoint

Wet air reduces the adsorptive capacity of the adsorbent material, reducing adsorption filter element / cartridge lifetime. Ideally, in-line 
adsorption filters should always be placed downstream of a compressed air dryer to prolong adsorption filter element / cartridge lifetime.

Compressor oil changes 

When compressor oil is changed, the new lubricant burns off “light ends” which increases the oil vapour content for hours or even weeks 
afterwards. This increase in oil vapour content is adsorbed by the adsorption filter element / cartridge, reducing the adsorption filter 
element / cartridge lifetime.
 

OIL-X Grade ACS Adsorption Filters

The performance of the OIL-X Grade ACS element is based upon a nominal inlet temperature of 21°C, with a pressure dewpoint of -40°C 
and a maximum oil vapour inlet concentration of 0.018mg/m3. Under these conditions, OIL-X Grade ACS will have a lifetime of 650 
hours. Operating OIL-X grade ACS at higher inlet temperatures / higher inlet oil vapour concentrations / or before a refrigeration or 
adsorption dryer will result in lower adsorption filter lifetime.  Replace the carbon filter element upon detection of vapour, odour or taste. 
OIL-X Grade ACS are recommended for point of use applications only where frequent element changes are acceptable.

OIL-X Grade OVR Adsorption Filter

s

Unlike in-line adsorption filters (OIL-X Grade ACS), OIL-X Grade OVR adsorption filters are sized and selected to not only provide 
consistent air quality but to also provide 12 months of cartridge life. This 12 month (6000 hours for models OVR 100 ~ OVR 250 and 
8736 hours for models OVR 300 ~ OVR 550) cartridge life is dependent upon sizing for the following inlet parameters: maximum inlet 
temperature / compressor type, minimum inlet pressure, position in system (before or after a dryer) and inlet oil vapour content. OIL-X 
Grade OVR adsorption filters are designed for both plant scale (compressor room) and point of use applications.

Содержание OIL-X PX010

Страница 1: ...L X COMPRESSED AIR FILTER Filters for Compressed Air USER GUIDE 17 118 6204 07 21 Rev Maintenance Guide 17 118 6201 Installation Setup Guide 17 118 6202 Filtration User Guide EN PX010 PX055 WS A0 AA A...

Страница 2: ...y Accessories Spare Parts Parker Worldwide Filter Weights and Dimensions System Depressurisation Filter Bowl Removal Removal of Element from Filter Bowl Automatic Drain Replacement Service Reminder La...

Страница 3: ...03 OIL X Compressed Air Filter User Guide 2019 INSTALLATION RECOMMENDATIONS...

Страница 4: ...ate may move when the filter is not pressurised The lower closure plate is a non serviceable item and should never be removed WS AO AA 90o Before pressurising the filter ensure that the head and bowl...

Страница 5: ...e purification equipment should be installed as close to the application as possible Purification equipment should not be installed downstream of quick opening valves and should be protected from poss...

Страница 6: ...06 OIL X Compressed Air Filter User Guide 2019 START UP PROCEDURE...

Страница 7: ...y open the inlet valve 01 to gradually pressurise the filter and wait 1 minute 02 before slowly opening the outlet valve 03 to re pressurise the downstream piping Note Do not open inlet or outlet valv...

Страница 8: ...08 OIL X Compressed Air Filter User Guide 2019 PRODUCT MAINTENANCE...

Страница 9: ...ld always be placed downstream of a compressed air dryer to prolong adsorption filter element cartridge lifetime Compressor oil changes When compressor oil is changed the new lubricant burns off light...

Страница 10: ...and depressurise the filter 03 using the drain Unscrew the filter bowl 01 02 and remove the used element 03 Note A strap wrench may be required for the removal of the 050 055 filter bowl 10 OIL X Comp...

Страница 11: ...LTER BOWL AUTOMATIC DRAIN REPLACEMENT Remove the element from the filter bowl Unscrew the automatic drain 01 and discard 02 Fit the new drain 03 and tighten 04 11 OIL X Compressed Air Filter User Guid...

Страница 12: ...with the new O ring provided Refit the filter bowl and head ensuring that the threads are fully engaged 01 and the locking details are aligned 02 Note To ensure that the bowl is fully engaged into th...

Страница 13: ...d write on the date the element is to be replaced i e 12 months after element change Slowly open the inlet valve 01 to gradually pressurise the filter and wait 1 minute 02 before slowly opening the ou...

Страница 14: ...Start up Procedure System De pressurisation Filter Bowl Removal Removal of Element from Filter Bowl Automatic Drain Replacement Insertion of Replacement Element into Filter Bowl Replacement of Filter...

Страница 15: ...15 TECHNICAL SPECIFICATION...

Страница 16: ...85 742 21 742 233 1695 21 233 1695 85 85 742 233 WS Minimum Inlet Pressure bar g 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 232 218 203 189 174 160 145 131 116 100 87 73 58 44 29 15 0 68 0 71 0 73 0 76 0...

Страница 17: ...ADE GRADE GRADE GRADE GRADE GRADE GRADE Minimum Inlet Pressure Correction Factor bar g 16 20 15 19 14 18 13 17 12 11 10 9 8 7 6 5 4 3 2 1 232 290 218 277 203 263 189 248 174 160 145 131 116 100 87 73...

Страница 18: ...ATION GRADE FILTER MODELS MIN OPERATING PRESSURE MAX OPERATING PRESSURE MIN RECOMMENDED OPERATING TEMP MAX RECOMMENDED OPERATING TEMP BAR G PSI G BAR G PSI G O C O F O C O F WS with float drain PX010...

Страница 19: ...41 6 87 0 81 2 66 1 41 1 41 6 87 2 66 8 47 7 09 10 91 20 26 7 09 17 32 9 37 17 32 7 09 10 91 9 37 9 37 17 32 10 91 20 26 6 06 9 13 21 33 6 06 15 07 7 95 15 07 6 06 9 13 7 95 7 95 15 07 9 13 21 33 2 9...

Страница 20: ...0 81 2 66 1 41 1 41 6 87 1 41 7 18 15 78 7 09 10 91 25 75 33 23 7 09 14 45 14 45 9 37 20 94 20 94 7 09 10 91 9 37 9 37 17 32 9 37 20 94 33 23 6 06 9 13 22 91 30 39 6 06 12 68 12 68 7 95 18 7 18 7 6 06...

Страница 21: ...20 015 020 035 045 035 045 035 045 050 055 050 055 050 055 010 055 010 055 TRK1 2 MBK1 1 MBK1 2 TRK3 2 MBK3 1 MBK3 2 TRK2 2 MBK2 1 MBK2 2 TRK4 2 MBK4 1 MBK4 2 TRK5 2 MBK5 1 MBK5 2 EM1 M12 FD 0001 ACCE...

Страница 22: ...AS1210 PED Standards used 1 5 21 Division Engineering Manager This declaration of conformity issued under the sole responsibility of the manufacturer Declaration 01 May 2021 Date Signature Parker Han...

Страница 23: ...ITALY Corsico MI Tel 39 02 45 19 21 parker italy parker com JP JAPAN Tokyo Tel 81 0 3 6408 3901 KR SOUTH KOREA Seoul Tel 82 2 559 0400 KZ KAZAKHSTAN Almaty Tel 7 7272 505 800 parker easteurope parker...

Страница 24: ...rformance is maintained Air quality continues to meet international standards Protection of downstream equipment personnel and processes Low operational costs Increased productivity and profitability...

Отзывы: