➁
Installation • OEM750
24
Internal Connections
External Devices
1
2
3
4
5
6
7
ACTØ4
ACTØ4
Step Output
Drive,
Oscilloscope,
etc.
• Minimum high level output: 4.26V
(source 24mA)
• Maximum low-level output: 0.44V
(sinks 24mA)
Direction Output
Step and Direction Outputs
CW (P
IN
3) & CCW (P
IN
4) L
IMIT
I
NPUTS
The OEM750X has two dedicated hardware end-of-travel
limits—clockwise (CW) and counterclockwise (CCW). When
you apply power to the OEM750X, these inputs are enabled—
the default active state is
high
. To test the OEM750X without
connecting the CW and CCW limits, you must disable the
limits with the
LD3
command. You can use the Limit Switch
Status Report (
RA
) and Input Status (
IS
) commands to moni-
tor the limits’ status, and the
OSA
command to change the
active level of the inputs. The figure represents a typical
configuration of these inputs.
Internal Connections
+5V
4.75K
Ω
HCT244
+5V
4.75K
Ω
HCT244
Normally Closed
Limit Switches
External Devices
CW Limit
CCW Limit
GND
1
2
3
4
5
6
7
8
• Maximum low-level input: 0.8V
• Minimum high level input: 2V
Limit Inputs
Содержание OEM750