➁
Installation • OEM750
14
3. Apply power. The OEM750’s green power LED should be on. If the red FAULT
LED is on, consult
Chapter 4, Troubleshooting.
This test assumes that your indexer’s motor resolution
is set to 25,000 steps/rev. This is the default motor
resolution setting for the OEM750
.
4. Using the indexer, send step pulses to the drive that will rotate the motor one CW
revolution (25,000 step pulses) at 1 rps (25,000 steps per second).
5. Using the indexer, send step pulses to the drive that will rotate the motor one
CCW revolution at 1 rps. The drive's default direction is CCW (i.e., if the direction
input is not activated, the motor will rotate CCW—if the direction input is activated,
the motor will rotate CW). If the motor does not rotate in the desired direction,
remove drive power and reverse the direction sense for your system by reversing
the motor leads going to the A+ and A- terminals.
WARNING
Never connect or disconnect any component to or from the drive with power
applied. System damage or personal injury may occur.
6. After verifying that the motor moves CW and CCW, turn off power.
Quick Test: OEM750X
1. Complete steps 1- 7 from the OEM750 Quick Test,
but turn DIP SW3-#3 ON to
disable the automatic test function.
2. Connect the OEM750X to an RS-232C communications device (i.e., computer,
PLC, etc.). The OEM750X's communication parameters are listed below:
• Baud Rate:
9600
• Data Bits:
8
• Stop Bit:
1
• Parity:
None
Handshaking is not supported. Terminals should be set for full duplex mode. The
next drawing shows pins to use for transmit, receive, and ground.
1
7
14
15
Transmit
Receive
14
15
25 Pin
D-Connector
on OEM750X
Ground
7
7
5
0
IN
DEX
ER
7
5
0
IN
DE
XER
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
Test Configuration – OEM750X RS-232C Connections