background image

NITROGEN GENERATORS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 

Aerospace Filtration Division

Greensboro, North Carolina

336 668 4444

Bioscience & Water  

Filtration Division

Bioscience Filtration

Oxnard, California

877 784 2234

Water Purification

Carson, California

310 608 5600

Engine Mobile  

Aftermarket Division

Kearney, Nebraska

308 234 1951

Engine Mobile Original  

Equipment Division

Modesto, California

209 521 7860

 

HVAC Filtration Division

Jeffersonville, Indiana

866 247 4827

Hydraulic & Fuel  

Filtration Division

Metamora, Ohio

419 644 4311

Industrial Gas Filtration &  

Generation Division

Lancaster, NY

800 343 4048

Industrial Pro cess  

Filtration Division

Mineral Wells, Texas

940 325 2575

Bioscience Engineering  

Filtration Division EMEA

Birtley, United Kingdom

+44 (0) 191 410 5121

Engine Mobile Filtration  

Division EMEA

Dewsbury, United Kingdom

+44 (0) 1924 487 037

Gas Separation &  

Filtration Division EMEA

Team Valley, United Kingdom

+44 (0) 191 402 9000

Gas Turbine Filtration Division

Alton, United Kingdom

+44 (0) 1420 541188

Hydraulic & Industrial  

Filtration Division EMEA

Arnhem, Netherlands

+31 (0) 26 376 0376

Australia Filtration Division

Castle Hill, Australia

+61 2 9634 7777

China Filtration Division

Shanghai, China

+86 21 2067 2067

India Filtration Division

Chennai, India

+91 22 4391 0700

Korea Filtration Division

Hwaseon City, Korea

+82 31 359 0852

Latin America Filtration Division

Sao Paulo, Brazil

+55 12 4009 3500

Parker Filtration Group

Bulletin TI-N2-120 Rev. A 032022

© 2022 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies.

Parker Hannifin Corporation

Industrial Gas Filtration and Generation Division

4087 Walden Avenue

Lancaster, NY 14086

phone 800 343 4048

www.parker.com/igfg

Содержание N2-120

Страница 1: ...Nitrogen Generator Installation Operation Maintenance Manual Models N2 120 N2 160 N2 240...

Страница 2: ...NITROGEN GENERATORS INSTALLATION OPERATION AND MAINTENANCE MANUAL 1...

Страница 3: ...ty 11 8 NITROGEN FLOW AT GIVEN OPERATING PRESSURE AND PURITY 12 9 OPERATION ADJUSTMENT PROCEDURES 14 9 1 Atmospheric Pressure Applications 10 psig 0 7 barg 14 9 2 Elevated Pressure Applications 10 psi...

Страница 4: ...of purchase when this product is operated and maintained according to the instructions provided with the product then Parker guarantees at Parker s option to replace the product repair the product or...

Страница 5: ...manual and by other safety governing bodies will void the safety certification of this product Any modification of the product will void the warranty If you have any questions or concerns please call...

Страница 6: ...100 psig 6 9 barg outlet pressure To achieve this outlet pressure the inlet pressure needs to be approximately 110 115 psig 7 6 7 9 barg 4 ENGINEERED SYSTEM The Parker N2 120 N2 160 and N2 240 Nitrog...

Страница 7: ...er rate than nitrogen molecules This differential permeation results in a high purity dry nitrogen gas stream exiting the membrane module The oxygen enriched permeate stream is exhausted through ports...

Страница 8: ...tration in a process stream It can be easily installed on top of the nitrogen generator and connected to the outlet nitrogen line using appropriate fittings 6 INSTALLATION All installation operation a...

Страница 9: ...tor to up to 2 instruments and to the compressed air supply See Figure 4 for the recommended installation schematic Shutoff Valve A shutoff valve should be installed directly upstream from the nitroge...

Страница 10: ...air at room temperature and relatively free of water compressor oil hydrocarbons and particulate matter An oil content 0 01 mg m3 is recommended The dewpoint of the incoming air is recommended to be l...

Страница 11: ...rker Nitrogen Generator and the receiver tank see Figure 5 The Balston 72 460 V883 Back Pressure Controller contains both components and may be ordered as an accessory for the Nitrogen Generator The a...

Страница 12: ...ust be constant for the system to supply nitrogen of consistent purity to the application The inlet pressure to the Parker Nitrogen Generator should be maximized within process and generator parameter...

Страница 13: ...0 PSIG 100 PSIG 125 PSIG 145 PSIG Meter SLPM Meter SLPM Meter SLPM Meter SLPM Meter SLPM Meter SLPM Meter SLPM 99 50 0 7 32 0 9 43 1 1 54 1 3 66 1 5 78 1 9 110 2 1 133 99 00 1 0 43 1 2 55 1 5 71 1 7 8...

Страница 14: ...r SLPM Meter SLPM Meter SLPM Meter SLPM 99 50 0 9 23 1 3 34 1 6 47 2 0 60 2 2 75 2 5 88 2 7 100 99 00 1 2 30 1 6 44 2 2 63 2 7 81 2 9 100 3 4 119 3 7 138 98 00 1 7 43 2 3 63 3 0 88 3 7 113 4 2 144 4 8...

Страница 15: ...en at or near atmospheric pressure e g purging or blanketing applications use the following procedure for start up and adjustment of the system 1 Open the customer installed inlet air gate valve 2 Adj...

Страница 16: ...djust the customer installed inlet air pressure regulator until the Operating Pressure gauge see Figure 1 shows the pressure required to deliver nitrogen at the desired flow rate per flowmeter adjustm...

Страница 17: ...nerator to the proper reading as specified by the Flowmeter Adjustment Label 6 Purge the entire system venting the initial nitrogen stream through the vent valve to atmosphere Purge time is dependent...

Страница 18: ...9 7 Shutting Down Proper shutdown of the Parker Nitrogen Generator can be accomplished by simply closing the customer supplied inlet air gate valve see Figure 4 or 5 If this valve is left open the sy...

Страница 19: ...1B1 BX filter assemblies Replace these filter cartridges with Balston 100 18 DXE and 100 18 BXE filter cartridges When replacing the prefilter cartridges be sure to install the proper grade filter in...

Страница 20: ...o the generator and allow the system to depressurize 2 Disconnect the upper hose from the filter using the 7 8 open end wrench 3 Remove the two lockdown knobs to release the filter 4 Disconnect the lo...

Страница 21: ...essure Drop 15 psig 0 7 barg Min Max Ambient Operating Temp 34 F 140 F 1 C 60 C Recommended Ambient Operating Temp 68 F 20 C Max Relative Humidity 80 Altitude 2000 m Max Min Max Inlet Air Temp 40 F 13...

Страница 22: ...is nontoxic and largely inert It can act as a simple asphyxiant by displacing oxygen in air Inhalation of nitrogen in excessive concentrations can result in uncon sciousness without any warning sympto...

Страница 23: ...fied Check setting of flow rate Check the operating pressure to assure that it has not varied from the original reading Check the system for leaks Calibrate oxygen analyzer if needed Air Leak Through...

Страница 24: ...410 5121 Engine Mobile Filtration Division EMEA Dewsbury United Kingdom 44 0 1924 487 037 Gas Separation Filtration Division EMEA Team Valley United Kingdom 44 0 191 402 9000 Gas Turbine Filtration Di...