22
NITROGEN GENERATORS
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
12. TROUBLESHOOTING
Symptom -
Nitrogen
Generator
Course of Action
Loss of Outlet
Pressure
Check that the flow control valve on the generator is fully open and control the flow
with a valve at the process.
Check operating pressure to assure that it is greater than 80 psig (5.5 barg).
Check the system for leaks.
Loss of Outlet Flow
Check operating pressure to assure that it is greater than 80 psig.
Check setting of flow control valve. Adjust if necessary.
Check the system for leaks.
Purity is Lower
than Specified
Check setting of flow rate.
Check the operating pressure to assure that it has not varied from the original reading.
Check the system for leaks.
Calibrate oxygen analyzer (if needed).
Air Leak Through
Drains of Prefilters
Check inlet pressure. It should be greater than 15 psig (1 barg) to seal drain.
Remove tubing from the drain outlet, hold finger over drain opening for a few
seconds to allow pressure to build and drain to seal.
Remove bowl from filter assembly and rinse with water.
If leak persists, replace automatic float drain (P/N 21552).
If issue remains unresolved, please call the Technical Services Department at 1-800-343-4048,
8 AM to 5 PM Eastern Time or email at [email protected] (North America only). For other
locations, please contact your local representative.