OBJECT DESCRIPTION
INDEX
6061h
Name
Modes of operation display
Object Code VAR
Data Type
INTEGER8
Category
Mandatory
ENTRY DESCRIPTION
Access
ro
PDO Mapping Possible
Value Range
INTEGER8
Default Value No
DATA DESCRIPTION Same as for object 6060
h
modes of operation
.
NOTE The actual mode is reflected in the
modes of operation display
(index 6061
h
), and not
in the m
odes of operation
(index 6060
h
).
6.1.3
Functional description
6.1.3.1
Modes of operation function
The device behaviour depends on the activated modes of operation
.
It is possible to implement different device modes. Since it is not possible to operate the
modes in parallel, the user is able to activate the required function by selecting a mode of
operation. An example of exclusive functions are those for position and torque control, which
can only control one variable at any one time. The variables can perform at most a limited
function. Such hybrids are regarded as the particular characteristics of a mode of operation.
Position control operation and encoder profile support can be active at the same time, for
example. Consequently encoder profile support is not regarded as a mode of operation.
Operation mode
function
Modes of
operation
(6060h)
Modes of
operation display
(6061h)
Velocity mode
Profile velocity mode
Profile torque mode
Содержание MDC Series
Страница 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Страница 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Страница 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Страница 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Страница 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Страница 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...
Страница 57: ...www runcheng net www runcheng net...