Installation
EN
9
3 Installation
3.1 System layout and location
Please refer to diagram A4 in annex A.
Only competent personnel trained, qualified, and approved by Parker domnick hunter should perform
installation, commissioning, service and repair procedures.
Ref
Description
Ref
Description
1
Compressor
8
Buffer Vessel
2
Oil / Water Separator
9
Pressure Relief Valve
3
Wet air receiver
10
Dust Filter
4
Water separator
11
Maxi Generator
5
Dryer pre-filtration
12
Nitrogen Outlet
6
Pre-treatment Dryer
13
Non Return Valve
7
Dust Filter
Isolation Valve
The generator should be located indoors on a flat surface and protected from direct
sunlight, moisture, and dust (Refer to section 2.1 of this user guide for the generators
environmental specification). When considering the final location, take into account the
noise generated when in use.
Lift the generator by the lower manifold, using a fork lift truck or similar, and position it
in a suitably ventilated area close to the application.
Note: Due to the nature of operation there is a possibility of oxygen enrichment
surrounding the generator.
Ensure that there is sufficient free space for maintenance access and lifting
equipment.
DO NOT position the generator so that it is difficult to operate or disconnect.
When positioned in its final location, secure the generator to the floor using M20 bolts
through the support legs.
Due to the nature of operation there is a possibility of oxygen enrichment surrounding the generator. Ensure that the
area is adequately ventilated. Where the risk of oxygen enrichment is high, such as a confined space or poorly ventilated
room, the use of oxygen monitoring equipment is advisable.