Maintenance work to be completed every 48 months
48
K-MT1-8_EN_08—2014
Risk of skidding!
If drying agent has been spilt on the floor, there is a risk of skidding
caused by the drying agent beads. Therefore, spilt drying agent must
always be taken up immediately.
Remove used drying agent
►
Use an industrial vacuum cleaner to hoover up carefully the drying agent
out of the chambers.
Warning!
If the dryer is not used within specifications, the drying agent can be
contaminated with pollutants. Always take this into account for the
environmentally safe disposal of the drying agent. The waste code
numbers of the drying agent can be obtained from the manufacturer.
►
Dispose of the used drying agent in accordance with all applicable
regulations.
Before filling in new drying agent, we recommend that you replace the demister
and the seal.
Replacing the lower perforated plate
►
Loosen the screws on the solenoid
valve plate.
►
Remove and replace perforated
plate and demisters.
Loosen the solenoid valve plate
Reaffix the solenoid valve plate:
►
Use a dyamometric key to tighten
the screws, and take care to observe
the following torques:
—
25 Nm in the case of K-MT 1-4
—
50 Nm in the case of K-MT 6-8
►
Tighten the screws crosswise in
accordance with the sequence
shown on the right.
►
Repeat the process once.
Correctly affixing the solenoid valve plate
Next the new drying agent should fill up.