Failure modes
Appendix B
Instruction book, IQAN-MC3
Off
Failure mode
Detected
Comment
DOUT open
•
DRET open
•
DOUT short circuit to DRET
No influence on function in this state.
DOUT short circuit to +BAT
Reverse feed *.
No influence on function in this state.
DOUT short circuit to -BAT
•
Detected, or fuse blows.
DRET short circuit to +BAT
Reverse feed *.
No influence on function in this state.
DRET short circuit to -BAT
•
Current through load, < 100 ms
DOUT short-circuit to 2
nd
DOUT (active/
passive)
No influence on function in this state.
DOUT short-circuit to 2
nd
COUT (active)
•
DOUT short-circuit to 2
nd
COUT
(passive)
No influence on function in this state.
DOUT short circuit to 2
nd
CRET (active)
No influence on DOUT (error detected
on 2
nd
COUT).
DOUT short circuit to 2
nd
DRET (active)
•
Detected, or fuse blows.
DOUT short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
DRET short circuit to 2
nd
DRET (active)
•
DRET short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
Содержание iqan-mc3
Страница 1: ...IQAN MC3 Instruction book Publ no HY33 8001 IB UK Edition 2016 05 16...
Страница 18: ...15 Markings Approvals 4 Safety Instruction book IQAN MC3 Markings Approvals...
Страница 19: ...16 Markings Approvals 4 Safety Instruction book IQAN MC3...
Страница 20: ...17 Markings Approvals 4 Safety Instruction book IQAN MC3...
Страница 21: ...18 Markings Approvals 4 Safety Instruction book IQAN MC3...
Страница 22: ...19 Markings Approvals 4 Safety Instruction book IQAN MC3...