51
Error codes, messages and actions
Appendix B
Instruction book, IQAN-MC3
Appendix B
Error codes, messages and actions
If one of the following error is detected, a message will be presented with an error code
on the module. In some cases, the module will turn off or at least shut down the outputs,
to increase safety.
W
ARNING
Do not use the machine if an error message or error code is activated.
LED indicator showing different MC3 modes
Status Flash
(yellow)
Normal operation
Application not loaded
No application available
Waiting for restart
Error
code
Error
Primary Flash (red)
Error category
Secondary Flash (yellow)
Error description
1:1
Output
1:2
Input
1:3
VREF
2:1
Power Supply
2:2
Temperature
3:1
CAN, no contact
3:2
IDtag error
3:3
System mismatch
3:4
CAN error (bus off)
4:1
Internal error/OSE
4:2
Critical Temperature
4:3
a
a.Possible cause of 4:3 error is reverse feed of voltage on start-up.
Critical Stop