55
Failure modes
Appendix B
Instruction book, IQAN-MC3
Off
Failure mode
Detected
Comment
COUT open
•
CRET open
•
COUT short circuit to CRET
No influence on function in this state.
COUT short circuit to +BAT
Reverse feed *.
No influence on function in this state.
COUT short circuit to -BAT
•
CRET short circuit to +BAT
Reverse feed *.
No influence on function in this state.
CRET short-circuit to -BAT
•
CRET+ short-circuit to CRET-
No influence on function in this state.
COUT short-circuit to 2
nd
COUT
No influence on function in this state.
COUT short-circuit to DOUT (active)
•
COUT short-circuit to DOUT (passive)
No influence on function in this state.
COUT short circuit to 2
nd
CRET/DRET
(active)
No influence on COUT (error detected
on 2
nd
COUT/DOUT).
COUT short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
CRET short circuit to 2
nd
CRET/DRET
(active)
•
CRET short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.