Parker Hannifin Corporation
22
GB
High pressure connection setup
High pressure is defined for this unit as more than 2.5 bar, with a maximum of 350 bar.
We recommend that the icountOS is positioned in a safe, stable area, as close as possible to the
system output and only the hose fittings provided are used.
The icountOS (IOS1220) is supplied with Low Pressure hoses (ACC6NN031) and Pressure
Reducing valve (PRV) (ACC6NN027). High Pressure hoses are also available when connecting to
your system (ACC6NN034).
WARNING: The correct connection methods and safety standards must be applied
when using an icountOS with a high pressure system. Please follow the instructions in
this Handbook; contact Parker Hannifin for advice if in doubt.
Assembling the PRV and hose fittings
1
2
3
Orientate PRV removal tool
Press firmly
Removal tool located
4
5
6
Attach
OUTLET
(Ø 4mm) hose
Remove PRV cap
Add pressure fitting pipe
7
8
9
Press PRV firmly into
INLET
port
Check for flush fitting
Connect PRV to your
hydraulic system.
Содержание icountOS