10.6 Connecting terminal posts
WARNING
High current - risk of personnel injury and/or damage to equipment
To avoid burning or overheating of the high-current terminals, ensure that the correct torque
is applied to screws or nuts at production, and that proper screw length is used.
NOTE
The motor connections (U, V, and W) are not interchangeable and shall be connected to the
corresponding terminals on the motor.
NOTE
Make sure that the battery polarity is correct and do not activate the main contactor until the
capacitors are charged up to the predefined voltage. The capacitors will not charge to the
proper level if polarity is reversed.
The following sub-chapters describe recommended assembly materials (not included with product) for the
different motor controller models.
Table 12 describes the power terminal connections on the motor controller.
Terminal name Description
B+
Terminal for on-board fuse (optional). There is no connection to internal circuitry from this
terminal.
+
Positive supply to the power stage. (When external fuse is used connection is made directly to this
terminal.).
B-
Battery negative terminal.
U, V, W
Motor U, V, W -phase terminal.
Table 12 Motor controller power terminal connections