5. Maintenance
The recommended Service procedures identified in table 5.2 and all other repair and calibration work should be undertaken by a
domnick
hunter
trained, qualified and approved engineer.
5.1
Cleaning
Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may use a mild
detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.2
Service Intervals
Description Of Maintenance Required
Typical Recommended Maintenance
Interval
Component
Operation
Dail
y
W
eek
ly
6Mon
ths
4000 Hr
s
12 Months
8000 Hr
s
24
Months
16000 Hr
s
36 Months
24000 Hr
s
Generator
Check POWER ON indicator located
on control panel is illuminated and
cycles from red to green
Generator
Check drain valve is discharging on
a regular basis.
Generator
Check for leaks
Generator
Check pressure gauges during
operation
Generator
Ensure there is ventilation clearance
around generator
Generator
Check condition of electrical supply
cables and conduits
Generator
Replace filters
Recommended Service A
Generator
Replace compressor (option 1 only)
Models: G2, G3, G4, G7
Recommended Service B
Generator
Replace compressor (option 1 only)
Models: G1, G5, G6, G8, G9
Recommended Service B
Generator
Replace Valves
Recommended Service C
- Check
- Replace
Table 5.2