4
Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden
Hydraulic Saw Motors
Series F11iP
Bulletin HY30-8251/UK
Application Guide
Please note:
- Parker Hannifin will assign a
specific model number to a
saw motor based on customer
application data (sprocket
number of teeth, cylinder
configuration, etc.).
- When the unit is delivered
from the factory, all valve
settings are sealed.
- Please refer to the ordering
information below.
Hydraulic fluids
The saw motor data shown in the specification above are valid
when operating on a high quality, mineral based fluid with a
minimum of contamination.
Hydraulic fluids type HLP (DIN 51524), ATF (automatic trans-
mission fluid), and API type CD engine oils are suitable.
Operating temperature
The fluid temperature in the main hydraulic system must not
exceed 70 °C; the drain fluid must not exceed 115 °C.
NOTE:
Fluid temperature should be measured at the utilized motor
drain port.
Viscosity
The ideal viscosity for the saw motor is 15–30 mm2/s (cSt).
When the hydraulic system has reached full operating temperature,
the drain fluid viscosity must not be lower than 8 mm2/s
(measured at the utilized motor drain port).
Max start-up viscosity: 1 000 mm2/s.
Filtration
Long saw motor life can be expected if fluid cleanleness meets
or exceeds 'ISO code 18/13' (according to ISO 4406).
Under normal operating conditions a filtration level of
10 μm (absolute) is recommended.
Standard model numbers
Model
Ordering
Number of chain
Sword feed
number
number
sprocket teeth
cylinder [mm]
F11-019-IL-CS-K-000-000-2-012/025
378 6315
12
40/25
F11-019-IL-WS-K-000-000-1-012/030
378 6316
12
40/30
F11-019-IR-WS-K-000-000-1-014/025
378 6317
14
40/25
F11-019-IR-WS-K-000-000-3-012/030
378 6318
12
40/30
Specifications
Basic motor frame size
F11-19
Displacement
[cm
3
/r]
19.0
Pressure
(at the motor) [bar]
max intermittent
1)
300
max operating
280
min operating
220
min stand-by
20
Case pressure
2)
[bar]
max
6
min
3
Max shaft speed
[rpm]
10 000
Min flow
[l/min]
210
3)
Shaft torque
(theor.)
at 100 bar [Nm]
30.2
Mass moment of inertia
(x10
-3
) [kg m
2
] 0.88x10
-3
Weight
[kg]
17
Soleniod valve
Voltage [VDC]
24
Current [A]
0.6
Power [W]
14
Connector Deutsch
DT04-2P
1) Max 6 seconds in any one minute
2) Should be measured at drain port D
3) Min flow with a 12-tooth chain sprocket
(min 195 l/min with a 13-tooth sprocket
and min 180 l/min with a 14-tooth sprocket)
Code
Motor type
I
Saw motor with inte-
grated speed and
pressure controls
Code Motor rotation
L
Left hand
(counter clockwise)
R
Right hand
(clockwise)
Code Flange type
C
CETOP
W
Saw motor
flange
Code Seal type
S
Fluorocarbon
Code Shaft
K
Key shaft
Code Version
000
Factory
assigned
Code Flange
position
1
0°
2
90°
3
180°
Code No. of
teeth
012
12
013
13
014
14
Code Cylinder [mm]
025
40/25
030
40/30
Code Options
000
Factory
assigned
F11
000
000
012
025
019
I
–
–
–
–
–
–
–
–
/
L
C S
K
2
Example:
Basic
motor
Displacement
[cm
3
/r]
Motor
type
Flange-
type
Flange
orientation
Version
number
Specific
options
Chain
sprocket
Bar feed
cylinder
Shaft
type
Shaft
seal
Motor
rotation
Ordering information