4
Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden
Service Manual
Series F11
Bulletin HY30-5503-M1/UK
1)
Intermittent: max 6 seconds in any one minute.
2)
Self priming speed valid at sea level.
Specifications
Size F11
-5
-6
-10
-12
-14
-19
Displacement
(cm
3
/rev)
4,9
6,0
9,8
12,5
14,3
19,0
Operating Pressure
(bar)
Max intermittent
1)
Max continuous
420
350
420
350
420
350
420
350
420
350
420
350
Motor operating speed
(rpm)
Max intermittent
1)
Max continuous
Min continuous
14000
12800
50
11200
10200
50
11200
10200
50
10300
9400
50
9900
9000
50
8900
8100
50
Max pump self priming speed
(rpm)
L or R operation
2)
4600
-
4200
3900
3900
3500
Motor input flow
(l/min)
Max intermittent
1)
Max continuous
69
63
67
61
110
100
129
118
142
129
169
154
Main circuit temp.
Max (°C)
Min (°C)
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
Mass moment of inertia
(x10
-3
) (kg m
2
)
7,8
9,5
15,6
19,8
22,7
30,2
Weight
(kg)
4,7
7,5
7,5
8,2
8,3
11
Operating temperature
The following temperatures should not be exceeded
(Type
N
shaft seals): Drain fluid: 90 °C.
FPM shaft seals (type
V
) can be used to 115
°C
drain fluid temperature.
Note:
The temperature should be measured at the
utilized drain port.
Continuous operation may require case flushing in
order to meet the viscosity and temperature limitations.
For further information we refer to:
Catalogue HY30-8249/UK