4
DUSTHOG PNP Series
2.2 Equipment Description
This section will briefly describe each component in the PNP and its role in the system’s operation.
Dust Drawer
Most units will include a dust drawer where all collected fume or dust will fall into during filter cleaning.
Angled flanges will direct dust that is blown off of the primary filters into a dust bin. Behind the lowest
door on each cabinet, one 20 gallon bin will be housed behind each door of the cabinet (drawer quantity
dependent on unit size). They can be accessed and maneuvered to a disposal site where an easy-empty
design allows for disposal or recycling of collected material.
Filter Cabinet
The filter cabinet consists of the primary cartridge filters which are accessed through a hinged door on
the front of the module. The filters are moved in and out of the cabinet and sealed to the tubesheet with
a cambar mechanism.
The PNP comes standard with ProTura DH nanofiber technology cartridge filters. Additional media options
and filter configurations are available and may have been specified for your application.
Pulse Cleaning System/Blower Cabinet
The compressed air pulse cleaning system is used to dislodge collected contaminates from the filters
with bursts of air directed through cleaning nozzles. One filter is cleaned at a given time by controlling
the solenoids on the manifold with the cleaning system programmed into the touch screen display.
The controls for the cleaning system and all other electronics are housed in this cabinet.
The compressed air supply connection is located on the rear of the cabinet.
The system control panel is located at the front of the module on a tool operated, hinged access panel.
The supply power for the system is located at the rear of the cabinet.
The blower(s) is also located within this module immediately above the pulse cleaning system. The blower
is an Electronically Commutated (EC) motorized impeller assembly. Depending on airflow requirements,
there may be several blowers in this compartment installed in parallel.
2.3 Principal of Operation
The purpose of the PNP is to collect fugitive dust generated by various industrial processes during operation.
The collected fume or dust is pulsed off of the primary filters directly back into the unit dust drawer. The dust
bin can be emptied directly into a drum or container of the customers choice for recycling or disposal.
Differential Pressure
Differential pressure, also referred to as pressure drop (ΔP), is an indication of the resistance to airflow
across the filter elements. Differential pressure is commonly measured in inches of water column (W.C.).
It is normal for the differential pressure to increase as the collector operates. Any sudden increase or
decrease in differential pressure may indicate a problem in the collector (blinded filters, leaks or other
cause) that requires immediate attention. See troubleshooting guide in section 6 for assistance.
The operating differential pressure displayed on the unit will typically run between 0.5 to 3.0 in. W.C.
(124.4 to 746.5 Pa) for a primary cartridge. The expected pressure range for the after-filters is
0.5 to 3.0 in. W.C. (124.4 to 746.5 Pa).
Содержание DUSTHOG PNP
Страница 1: ...DUSTHOG Plug Play Fume Dust Collector Owner s Manual Model PNP...
Страница 6: ...Page intentionally left blank...
Страница 9: ...5 DUSTHOG PNP Series Figure 1B PNP Equipment Description 61 10120 Figure 1A PNP Equipment Description...
Страница 11: ...7 DUSTHOG PNP Series 61 10121 Figure 2 PNP Weights and Lifting Info...
Страница 27: ...23 DUSTHOG PNP Series Page intentionally left blank...
Страница 29: ...25 DUSTHOG PNP Series PNP 12 Figure 24 PNP Replacement Parts 61 10123...
Страница 30: ...26 DUSTHOG PNP Series A1 Transformer 575 480 8 Appendix Wiring Diagrams 04 001886...
Страница 31: ...27 DUSTHOG PNP Series A2 One Blower Controls 04 001830...
Страница 32: ...28 DUSTHOG PNP Series A3 Two Blower Controls 04 001831...
Страница 33: ...29 DUSTHOG PNP Series A4 Three Blower Controls 04 001832...
Страница 34: ...30 DUSTHOG PNP Series A5 Four Blower Controls 04 001881...
Страница 35: ...31 DUSTHOG PNP Series A6 Remote Panel Controls 04 001868...
Страница 36: ...32 DUSTHOG PNP Series A7 One Blower Remote Controls 04 001833 A7...
Страница 37: ...33 DUSTHOG PNP Series A8 A8 Two Blower Remote Controls 04 001834...
Страница 38: ...34 DUSTHOG PNP Series A9 Three Blower Remote Controls 04 001863...
Страница 39: ...35 DUSTHOG PNP Series A10 Four Blower Remote Controls 04 001864...