412LXR Series Product Manual
Chapter 2 - 412LXR Series Table Specifications
17
Electrical Specifications
Parameter
12 Pole
Units
Continuous Force
1
355
N
Continuous Current
1,4,8
6.3
Amps Peak
Continuous Current
1,7
5.5
Amps DC
Peak Force
6
1000
N
Peak Current
4,6,8
19.0
Amps Peak
Peak Current
6,7
16.4
Amps DC
Voltage Constant
3,4
65
Volt/m/sec
Force Constant
9
56.3
N/Amps Peak
Force Constant
3,4
65
N/Amps DC
Resistance
3
9.98
Ohms
Inductance
5
5.68
mH
Maximum Bus Voltage
340
Volts DC
Thermal Resist. Winding-Ambient
0.24
C/watt
Viscous Damping
40
N/m/s
Static Friction
13
50
N
Intermit Force Duration
10
160
Seconds
Peak Force Duration
11
63
Seconds
Magnetic Attraction
2
2000
N
Electrical Pitch
12
42
mm
Mass-Motor Carriage
12.3
Kg
Rated Winding Temp.
125
C/watt
Winding Class
H
-
1.
@ 25
o
C ambient, 90
o
C Winding Temperature
2.
Measured with a 0.70 mm gap
3.
Measured Line to Line +/-10%
4.
Value is measured peak of sine
5.
+/-30% Line to Line, inductance bridge measurement @1Khz
6.
Initial winding temperature must be 60
o
C or less before Peak Current is applied
7.
DC current through a pair of motor phases of a trapezoidal (six state) commutated motor
8.
Peak of the sinusoidal current in any phase for a sinusoidal commutated motor
9.
Total motor force per peak of the sinusoidal amps measured in any phase, +/-10%
10. Maximum time duration with 2 times rated current applied with initial winding temperature at 60
o
C
11. Maximum time duration with 3 times rated current applied with initial winding temperature at 60
o
C
12. The Distance from the leading edge of the north pole to the leading edge of the next north pole