Mounting Surface Requirements
Proper mounting of the 412LXR is essential to optimize product performance. All
specifications are based on the following conditions:
•
The positioner must be bolted down along its entire length.
•
The positioner must be mounted to a flat, stable surface, with a flatness error less than or equal to
0.013mm/300mm.
•
Catalog specifications may deviate for positioners mounted to surfaces that do not meet the above
conditions.
•
If the surface does not met these specifications the surface can be shimmed to comply with these
requirements.
•
If mounting conditions require that the table base is overhung, table specifications will not be met over that
portion of the table. Additionally, in X-Y Systems the overhung portion of the Y-axis may not met specifications
due to the additional error caused by deflection and non-support of the base. Contact Daedal for guidelines on
specifications of overhang applications.
Mounting Methods
The 412LXR can be mounted via the three (3) following methods:
314.0 Ctr'd
336.0 Ctr'd
240.0 Ctr'd
240 Ctr'd
Toe Clamp
M6 SHCS
Toe Clamp Mounting
P/N 100-6766-01
Three (3) M6 SHCS Per Toe Clamp
Minimum Depth of 9 mm
Maximum Height of 20 mm
Base Through Holes
Use M6 SHCS
Note: Minimum Screw Length of 22 mm
Bottom Tapped Holes
Use M8 SHCS
Note Maximum Length