404LXR Series Product Manual
Chapter 5 - Connecting the Gemini Amplifier
36
VM25 Pin Outs**
6K Axis Number
1
2
3
4
5
6
7
8
Connect to external power supply (see above)
21 15 9
3 21 15 9 3
23 17 11 5 23 17 11 5
19 13 7
1 19 13 7 1
All even pins are connected to logic ground.
Function Wire Color* LXR
Pin #
+5 to +24VDC
Red
A
(-) Limit
Blue B
(+) Limit Orange C
Home
Green D
Ground
Black E
LXR Limit/Home Cable
P/N 006-1742-0X
VM25
Module
* Color scheme of the flying leads from the Limit/Home Cable. P/N 006-1742-0X.
** Axes 1-4 use the first 25-pin limits/home connector and axes 5-8 use the second limits/home connector on the 6K.
External
+24 VDC
Supply
+5 to +24VDC Limit/Home (Red)
Содержание Daedal 400LXR Series
Страница 8: ...404LXR Series Product Manual Chapter 1 Introduction 8 Assembly Diagrams Strip Seal Version ...
Страница 9: ...404LXR Series Product Manual Chapter 1 Introduction 9 Hardcover Version ...
Страница 11: ...404LXR Series Product Manual Chapter 2 404LXR Series Table Specifications 11 Dimensional Drawings ...
Страница 15: ...404LXR Series Product Manual Chapter 2 404LXR Series Table Specifications 15 ...