Chapter 1. Installation
9
Motor Drivers
PIN OUTS & SPECIFICATIONS
(15-pin DRIVE Connector)
15 D
Pin #
Cable
(71-010432-10)
Color/25 D Pin #
In/Out
Name
Description
1
Red/1
OUT
Step (+)
Differential output. Step (pulse) output to the drive. Step + signal is active high.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
2
Green/2
OUT
Direction (+)
Differential output. High signal on Dir specifies motion in the positive
direction; Low signal on Dir specifies motion in the negative direction.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
3
—
—
Reserved
-----------------------
4
Gray/10
IN
In-Position
Used for digital servo drives to indicate that the motor has reached the target
position. HCMOS switching levels (Low
≤
1.0V, High
≥
3.25V). Voltage range: 0-5V.
5
Yellow/9
IN
Drive Fault
An active-high (current not flowing) signal that tells the AT6n00 a drive has faulted.
HCMOS switching levels (Low
≤
1.0V, High
≥
3.25V). You can use the
DRFLVL
command to change the active level to low (current flowing) if desired. NOTE: The
Drive Fault input will not be recognized until the input functions are enabled with the
INFEN1
command.
6
—
—
Reserved
-----------------------
7
—
OUT
+5V
Is5V.
8
Bare Wire/5
—
Shield
Connected to chassis (earth) ground within the AT6n00.
9
Black/14
IN
Step Return (-)
Differential output. Step (pulse) output to the drive. Step - signal is active low.
10
White/15
IN
Direction Return (-)
Differential output. Low signal on Direction - specifies motion in the positive
direction; High signal on Direction - specifies motion in the negative direction.
11
Blue/16
OUT
Shutdown (+)
Differential output. This signal is used to turn off current in the motor windings.
High
signal on Sh indicates the motor winding current should be off.
Signal levels: Low
≤
1.0VDC @ -30mA, High
≥
3.5VDC @ +30mA.
12
Purple/17
IN
Shutdown Return
(-)
Differential output. This signal is used to turn off current in the motor windings.
Low
signal on Shutdown - indicates the motor winding current should be off.
13
Orange/21
—
Ground
Isolated logic ground
14
Brown/22
—
Ground
Isolated logic ground
15
—
—
Reserved
-----------------------
INTERNAL SCHEMATICS
Step, Direction & Shutdown Outputs
+5VDC
GND
15-Pin
DRIVE
Connector
Step +
Dir
Sh
Step -
Direction -
Shutdown -
Shutdown Output Circuit Current Flow
(Active vs. Inactive)
Sh
Shutdown -
Current
Flow
(Active)
Current
Flow
(Active)
Current
Flow
(Inactive)
Current
Flow
(Inactive)
Drive Fault and In-Position Inputs
+5VDC
GND
74HCxx
1 K
Ω
15-Pin
DRIVE
Connector
Drive Fault or
In-Position
Ground
(pin 13 or 14)
15-Pin
DRIVE
Connector
+5VDC
GND
+5VDC
GND
+5VDC
GND
C O N N E C T I O N S
15-pin D
Connector
Drive
Motor
Plug-compatible with most
Compumotor and Digiplan drives
(exceptions are illustrated below).
Connect to DRIVE connector
25-pin D
Connector
Connect to drive
10-foot cables provided in ship kit (p/n 71-010432-10).
Maximum recommended cable length is 50 feet.
Pin outs and cable color code provided in table below.
71-010432-10
WARNING
Make sure the drive is off before
connecting it to the AT6n00.
Содержание Compumotor AT6200
Страница 5: ......