Parker EME
Setting up Compax3
192-120113 N08 C3I12T11 - December 2010
111
Example axis with the initiator signals
4
1
2
3
5
6
7
8
9
10
11
-
+
12
13
14
1:
Direction reversal / end switch on the negative end of the travel range
(the
assignment of the reversal / end switch inputs
(see on page 127) to travel range
side can be changed).
2:
Machine zero initiator (can, in this example, be released to 2 sides)
3:
Direction reversal / end switch on the positive end of the travel range
(the
assignment of the reversal / end switch inputs
(see on page 127) to travel range
side can be changed).
4:
Positive direction of movement
5:
Signals of the motor zero point (zero pulse of the motor feedback)
6:
Signal of the machine zero initiator
(
without inversion of the initiator logic
(see on page 127)).
7:
Signal of the direction reversal resp. end switch on the positive end of the travel range
(without inversion of the initiator logic).
8:
Signal of the direction reversal / resp. end switch on the negative end of the travel range
(without inversion of the initiator logic).
9:
Signal of the machine zero initiator
(
with inversion of the initiator logic
(see on page 127)).
10: Signal of the direction reversal resp. end switch on the positive end of the travel range
(with inversion of the initiator logic).
11: Signal of the direction reversal / end switch on the negative end of the travel range
(with inversion of the initiator logic).
12: Logic state of the home switch (independent of the inversion)
13: Logic state of the direction reversal resp. end switch on the positive end of the travel
range (independent of the inversion)
14: Logic state of the direction reversal resp. end switch on the negative end of the travel
range (independent of the inversion)
The following principle images of the individual machine zero modes always refer