background image

Parker EME

 

Safety instructions 

2.5 

Safety instructions 

 

2.5.1. 

General hazards 

General Hazards on Non-Compliance with the Safety Instructions 

The device described in this manual is designed in accordance with the latest 

technology and is safe in operation. Nevertheless, the device can entail certain 

hazards if used improperly or for purposes other than those explicitly intended. 

Electronic, moving and rotating components can 

 

cause danger for life and limb of the operator and

 

material damage

Designated use

The device is designed for operation in electric power drive systems (VDE0160).

Motion sequences can be automated with this device. Several motion sequences

can be can combined by interconnecting several of these devices. Mutual

interlocking functions must be incorporated for this purpose.

 

2.5.2. 

Working safely / qualification 

This device may be operated only by qualified personnel. 

Qualified personnel in the sense of these operating instructions consists of: 

 

Persons who, by virtue to their training, experience and instruction, and their

knowledge of pertinent norms, specifications, accident prevention regulations and

operational relationships, have been authorized by the officer responsible for the

safety of the system to perform the required task and in the process are capable

of recognizing potential hazards and avoiding them (definition of technical

personnel according to VDE105 or IEC364),

 

who have a knowledge of first-aid techniques and the local emergency rescue

services,

 

who have read and will observe the safety instructions,

 

who have read and observe the manual or help (or the sections pertinent to the

work to be carried out).

This applies to all work relating to setting up, commissioning, configuring, 

programming, modifying the conditions of utilization and operating modes, and to 

maintenance work. 

This manual and the help information must be available close to the device during 

the performance of all tasks. 

 

2.5.3. 

Special dangers 

 

Danger! 

Due to movable machine parts and high voltages, the device can pose a lethal 

danger. Danger of electric shock in the case of non-respect of the following 

instructions. The device corresponds to DIN EN 61800-3, i.e. it is subject to 

limited sale. The device can emit disturbances in certain local environments. In 

this case, the user is liable to take suitable measures. 

 

Check that all live terminals are secured against contact. Perilous voltage levels

of up to 850V occur.

 

Do not bypass power direct current.

 

Caution - Risk of Electric Shock! 

Always switch off devices before wiring them! 

Dangerous voltages are still present until 10 min. after switching off the power 

supply. 

 

 

 

The device must be permanently grounded due to high earth leakage currents.

 

The drive motor must be grounded with a suitable protective lead.

 

The devices are equipped with high voltage DC condensers. Before removing the

protective cover, the discharging time must be awaited. After switching off the

supply voltage, it may take up to 10 minutes (with additional capacity modules it

may take up to 30 minutes) to discharge the capacitors.

Danger of electric shock in case of non respect.

192-

120149N12 2017-09

Содержание C3Manager-Compax3H

Страница 1: ...r devices 192 120149 N12 2017 09 Release as from R09 63 We reserve the right to make technical changes 06 09 2017 192 120149N12 2017 09 The data correspond to the current status at the time of printin...

Страница 2: ...GmbH Co KG Electromechanical Drives Division EME Robert Bosch Strasse 22 77656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sale...

Страница 3: ...32 Bit 64 Bit Browser MS Internet Explorer 8 x or higher Processor Intel AMD Multi core processor 2GHz User 1024MB Hard disk 20GB available memory Monitor Resolution 1024x768 or higher Graphics card...

Страница 4: ...eakage current 11 2 7 4 Supply networks 11 2 8 EC declaration of conformity Compax3H 12 3 Mounting and dimensions C3H 13 3 1 Mounting distances air currents Compax3H050V4 14 3 2 Mounting distances air...

Страница 5: ...400VAC 480VAC 3 Unique number of the particular device 4 Nominal supply voltage Power Input Input supply data Power Output Output data 5 Designation of the feedback system F10 Resolver F11 SinCos Sing...

Страница 6: ...ironmental laws The following table states the materials suitable for recycling and the materials which have to be disposed of separately Material suitable for recycling Disposal Metal yes no Plastic...

Страница 7: ...mergency rescue services who have read and will observe the safety instructions who have read and observe the manual or help or the sections pertinent to the work to be carried out This applies to all...

Страница 8: ...x the devices according to the mounting instructions see on page 13 We cannot provide any guarantee for other mounting methods Note on exchange of options Device options must be exchanged in the facto...

Страница 9: ...ield connecting terminals furnished with the device The shield of the cable must also be connected with the motor housing The fixing via plug or screw in the terminal box depends on the motor type 100...

Страница 10: ...4 are not suitable for flat line bars Temperature rating of field installed conductors shall be at least 75 C Do only use copper lines Maximum Surrounding Air Temperature 45 C Motor overtemperature mo...

Страница 11: ...on the following factors Length and properties of the motor cable Switching frequency Operation with or without external mains filter Motor cable with or without shield network Motor housing groundin...

Страница 12: ...Introduction High power devices 2 8 EC declaration of conformity Compax3H 12 192 120149N12 2017 09...

Страница 13: ...tion Please provide for a sufficient mounting distance below and above the device in order to ensure free circulation of the cooling air Please do also respect the recommended distances of other devic...

Страница 14: ...nts Compax3H050V4 J I K M L mm I J K L M C3H050V4 15 5 25 70 70 3 2 Mounting distances air currents Compax3H090V4 J I K M L mm I J K L M C3H090V4 0 0 25 70 70 3 3 Mounting distances air currents Compa...

Страница 15: ...8VAC 50 60Hz Receiver current consumption 54Arms 82Arms 118Arms 140Arms Output current 43Arms 85Arms 110Arms 132Arms Maximum input fuse rating per device 80A 100A 160A 200A Recommended line protection...

Страница 16: ...Technical Data High power devices 16 192 120149N12 2017 09...

Отзывы: