background image

Technical Data

 

High power devices

 

16 

192-

120149N12 2017-09

Содержание C3Manager-Compax3H

Страница 1: ...r devices 192 120149 N12 2017 09 Release as from R09 63 We reserve the right to make technical changes 06 09 2017 192 120149N12 2017 09 The data correspond to the current status at the time of printin...

Страница 2: ...GmbH Co KG Electromechanical Drives Division EME Robert Bosch Strasse 22 77656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sale...

Страница 3: ...32 Bit 64 Bit Browser MS Internet Explorer 8 x or higher Processor Intel AMD Multi core processor 2GHz User 1024MB Hard disk 20GB available memory Monitor Resolution 1024x768 or higher Graphics card...

Страница 4: ...eakage current 11 2 7 4 Supply networks 11 2 8 EC declaration of conformity Compax3H 12 3 Mounting and dimensions C3H 13 3 1 Mounting distances air currents Compax3H050V4 14 3 2 Mounting distances air...

Страница 5: ...400VAC 480VAC 3 Unique number of the particular device 4 Nominal supply voltage Power Input Input supply data Power Output Output data 5 Designation of the feedback system F10 Resolver F11 SinCos Sing...

Страница 6: ...ironmental laws The following table states the materials suitable for recycling and the materials which have to be disposed of separately Material suitable for recycling Disposal Metal yes no Plastic...

Страница 7: ...mergency rescue services who have read and will observe the safety instructions who have read and observe the manual or help or the sections pertinent to the work to be carried out This applies to all...

Страница 8: ...x the devices according to the mounting instructions see on page 13 We cannot provide any guarantee for other mounting methods Note on exchange of options Device options must be exchanged in the facto...

Страница 9: ...ield connecting terminals furnished with the device The shield of the cable must also be connected with the motor housing The fixing via plug or screw in the terminal box depends on the motor type 100...

Страница 10: ...4 are not suitable for flat line bars Temperature rating of field installed conductors shall be at least 75 C Do only use copper lines Maximum Surrounding Air Temperature 45 C Motor overtemperature mo...

Страница 11: ...on the following factors Length and properties of the motor cable Switching frequency Operation with or without external mains filter Motor cable with or without shield network Motor housing groundin...

Страница 12: ...Introduction High power devices 2 8 EC declaration of conformity Compax3H 12 192 120149N12 2017 09...

Страница 13: ...tion Please provide for a sufficient mounting distance below and above the device in order to ensure free circulation of the cooling air Please do also respect the recommended distances of other devic...

Страница 14: ...nts Compax3H050V4 J I K M L mm I J K L M C3H050V4 15 5 25 70 70 3 2 Mounting distances air currents Compax3H090V4 J I K M L mm I J K L M C3H090V4 0 0 25 70 70 3 3 Mounting distances air currents Compa...

Страница 15: ...8VAC 50 60Hz Receiver current consumption 54Arms 82Arms 118Arms 140Arms Output current 43Arms 85Arms 110Arms 132Arms Maximum input fuse rating per device 80A 100A 160A 200A Recommended line protection...

Страница 16: ...Technical Data High power devices 16 192 120149N12 2017 09...

Отзывы: