Parker Hannifin Corporation •
Refrigerating Specialties Division
2445 South 25th Avenue • Broadview, IL 60155-3891
Telephone: (708) 681-6300 • Fax (708) 681-6306
VALVE
À
FPT FLANGES
WELDING FLANGES
Ã
FLANGES
SIZE
Nominal
Sock Weld
Weld Neck
Flange Package
Tubing
Fitting
Nom.
Flange
Pipe Size
Socket I.D.
Neck O.D.
Number(2/Pkg)
O.D.
I.D.
Flge Pkg.
Pipe Size
Pkg. No.
Á
Socket
Weld
Â
No. (2/Pkg)
mm
Inches
Inches
(2/Pkg) Inches NW No. Inches
mm
Inches
mm
Weld
Neck
Inches
mm
Inches
mm
20
3/4
3/4
200016
3/4
20
1.070
27.81
1.050
26.67 200020
200023
1-1/8
28.57
1.130
28.70
200027
and
and
1
200017
1
25
1.365
34.67
1.315
33.40 200021
200024
1-3/8
34.92
1.380
33.05
200028
25
1
1-1/4
200018
1-1/4
32
1.705
43.31
1.660
42.16 200022
200025
1-5/8
41.27
1.631
41.43
200029
1-1/4
200030
1-1/4
32
1.705
43.31
1.660
42.16 200032
200034
1-3/8
34.92
1.380
35.05
200036
32
1-1/4
1-1/2
200031
1-1/2
40
1.930
49.02
1.900
48.26 200033
200035
1-5/8
41.27
1.631
41.43
200037
2-1/8
53.97
2.131
54.13
200038
40
1-5/8
1-1/2
200039
1-1/2
40
1.930
49.02
1.900
48.26 200041
200043
1-5/8
41.27
1.631
41.43
200045
and
and
2
200040
2
50
2.445
62.10
2.375
60.33 200042
200044
2-1/8
53.97
2.131
54.13
200046
50
2
2-5/8
66.67
2.631
66.83
200047
65
2-1/2
2-1/2
200048
2-1/2
65
2.945
—
2.875
73.03 200049
200050
2-5/8
66.67
2.631
66.83
200051
3-1/8
79.37
3.131
79.53
200052
75
3
3
200053
3
80
3.575
90.81
3.500
88.90 200054
200055
3-1/8
79.37
3.131
79.53
200056
3-5/8
92.07
3.631
92.23
200057
100
4
4
200062
4
100
4.575 116.20
4.500 114.30 200063
200064
4-1/8
104.77
4.132
104.95
200065
À
FPT: Internal NPT (USA Standard Taper Pipe Thread).
Á
NW: Metric equivalent nominal size for steel tubing.
Â
Metric copper tubing used for refrigeration.
Ã
ODS connections to fit copper tubing of given outside
d
iameter. (Not for use with ammonia)
Definitions:
ODS - Outside Diameter Sweat
I.D. - Inside Diameter
O.D. - Outside Diameter
N.A. - Not Available
Flange Bolt Torque Requirements
Bolt Diameter
Valve Port Size
Torque
11mm (7/16")
13mm (1/2 ")
3.9 mkg (28 ft lb)
16mm (5/8")
20-50mm (3/4 "- 2")
11.8 mkg (85 ft lb)
19mm (3/4")
65-75mm (2-1/2 "- 3")
14.5 mkg (105 ft lb)
22mm (7/8")
100mm (4")
22.1 mkg (150 ft lb)
Safe Operation (See also Bulletin RSBCV)
People doing any work on a refrigeration system must be qualified
and completely familiar with the system and the Refrigerating
Specialties Division valves involved, or all other precautions will be
meaningless. This includes reading and understanding pertinent
Refrigerating Specialties Division product Bulletins, and Safety Bulletin
RSB prior to installation or servicing work.
Where cold refrigerant liquid lines are used, it is necessary that certain
precautions be taken to avoid damage which could result from liquid
expansion. Temperature increase in a piping section full of solid liquid
will cause high pressure due to the expanding liquid which can possibly
rupture a gasket, pipe or valve. All hand valves isolating such sections
should be marked, warning against accidental closing, and must not
be closed until the liquid is removed. Check valves must never be
installed upstream of solenoid valves, or regulators with electric shutoff,
nor should hand valves upstream of solenoid valves or downstream
of check valves be closed until the liquid has been removed. It is
advisable to properly install relief devices in any section where liquid
expansion could take place.
Avoid all piping or control arrangements which might produce thermal
or pressure shock.
For the protection of people and products, all refrigerant must be
removed from the section to be worked on before a valve, strainer, or
other device is opened or removed.
Flanges with ODS connections are not suitable for ammonia service.
Warranty
All Refrigerating Specialties Products are warranted against defect in
workmanship and materials for a period of one year from date of
shipment from factory. This warranty is in force only when products
are properly installed, field assembled, maintained and operated in
use and service as specifically stated in Refrigerating Specialties
Catalogs or Bulletins for normal refrigeration applications, unless
otherwise approved in writing by Refrigerating Specialties Division.
Defective products, or parts thereof, returned to the factory with
transportation charges prepaid and found to be defective by factory
inspection will be replaced or repaired at Refrigerating Specialties’
option, free of charge, F.O.B. factory. Warranty does not cover products
which have been altered or repaired in the field; damaged in transit,
or have suffered accidents, misuse, or abuse. Products disabled by
dirt, or other foreign substances will not be considered defective.
THE EXPRESS WARRANTY SET FORTH ABOVE CONSTITUTES
THE ONLY WARRANTY APPLICABLE TO REFRIGERATING
SPECIALTIES PRODUCTS, AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, WRITTEN OR ORAL,
INCLUDING ANY WARRANTY OR MERCHANTABILITY, OR
FITNESS FOR A PARTICULAR PURPOSE. No employee, agent,
dealer or other person is authorized to give any warranties on behalf
of Refrigerating Specialties, nor to assume, for Refrigerating
Specialties, any other liability in connection with any of its products.
FLANGES