2
DeviceNet Communications Interface
Figure 3. Front of 890 drive showing
Control Board fitted
2
1
1
Legacy 890 drive without
the STO feature
2
WARNING!
Before installing, ensure that the drive
wiring is electrically isolated and cannot be
made “live” unintentionally by other
personnel. Wait 5 minutes after
disconnecting power before working on
any part of the system or removing the
covers from the drives.
Figure 2. 890 showing Control Board
withdrawn with Options fitted
Installation
To Remove the Control Board
1.
Remove the blanking plates, each secured by
a single screw (1), that fits over the option
slots (1).
2.
Loosen the top and bottom screws from the
handles of the Control Board (2).
3.
Pull gently on the handles and slide the
Control Board (2) out of the drive.
Note:
Save the blank cover and screw for future
use. The drive should not be operated
without either an Option or a blanking
plate fitted. When fitted, these maintain
the drive's IP20 rating.
Caution
This Option contains ESD (Electrostatic
Discharge) sensitive parts. Observe static
control precautions when handling, installing
and servicing this Option.
Содержание 8903/DN