Parker Hannifin Corp.
Hydraulic Pump/Motor Div.
Greeneville, TN 37745 USA
11
(Reference Exploded Assembly View)
1.
Mount the motor in a soft jawed vice, shaft up, clamping on the
cover assembly. Remove manifold port o-rings if applicable.
SEE FIGURE D1
2.
Remove the 8 5/16-24 bolts (1)SEE FIGURES D2.
3.
Lift front bearing housing/flange (10) by lightly tapping the flange
up off the dowels with a soft hammer. Do not remove the dowel
pins., SEE FIGURES D3.
4.
Remove the locating ring carefully to prevent rollers from falling
or remove rollers with a magnet. SEE FIGURE D4.
Caution:
The rollers & check balls will fall out so
be ready to catch them to prevent
damage and loss.
Note:
The check balls may fall into the bolt
holes or into the commutator ports.
Figure D4
Figure D3
Figure D2
Figure D1