![Parker 6053-LINK-00 TechBox Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/parker/6053-link-00-techbox/6053-link-00-techbox_product-manual_756268015.webp)
10
LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5
Chapter 4 - Using DSD Macros and Templates
590+ and 690+ Macros/Templates
The DSD program has pre-configured macros for the 590+ and the 690+. These macros contain a
template for the specific drive. The internal drive parameters are programmed via the template and
are stored in the TechBox/TechCard. The macros are loaded every time the drive is energised; thus
all drive parameters are loaded into the volatile memory. DSD database properties of platform rev.
14-0, library rev. 115-0, instruction rev. 9-0 and class rev. 604-0, and all subsequent revisions.
Additional
LINK
function blocks may be inserted into the Techbox/Techcard configuration. The
Techbox/Techcard has approximately 2/3 of the memory capability of the L5300. In terms of
storage units the Techbox/Techcard has 4 units. A Section Control block requires 1 unit of storage,
SPW 3 winder block requires 2 units of storage.
590+ Macro
The 590+ macro is selected from the File/New drop down menu. There are two choices for the
590+, the L590P for armature current range 35 amps to 599 amps,and L590P-HP for armature
current range of 600 amps and higher. The L590P-HP template is also used for field weakening
applications when the armature currents are 300 amps and higher.
Select the applicable configuration for your drive. The program will prompt you for the address and
module name.