Operating the Converter
4-6
512C Series Converter
•
Adjust stability Potentiometer (P3) to improve transient response, note excessive adjustment
may cause instability.
Note:
The IR compensation potentiometer (P5) must be fully anticlockwise in Tachogenerator
control, adjustment will cause instability.
•
Monitor the armature current as indicated on terminal 6 the current meter output, verify that
that at steady state the current does not exceed the controller rating, i.e. the voltage on T6 is
not greater than 5V with SW8 OFF.